TROUBLESHOOTING
Manual 0463 413 001
6.02 Pre Power-up Checks
WARNING
Buss voltage of 400 VDC will be present on the heatsinks of POWER PCB2
while unit is on. Wait 40 seconds after removing power before handling.
Examine unit for any visible signs of damage.
In order to prevent tripping wall fuses and/or causing damage to the unit when power is applied, it is recom-
mended that the following components be checked prior to connecting unit to mains power:
1 MAINS POWER CABLE
INPUT POWER CABLE/PLUG
2
SW1
ON/OFF
SWITCH
3
CB1
CIRCUIT
BREAKER
4 VR1
VARISTOR on POWER PCB2
5 BR1/BR2
BRIDGE RECTIFIERS on POWER PCB2
6 PTC1/RY1
PTC1 (R79) & INRUSH RELAY (RY1) contacts in parallel on POWER
PCB2
7 D49 & D50
DIODES on POWER PCB2
8 Q19 & Q21
PFC TRANSISTORS on POWER PCB2
9 C35-3
WORKING CAPACITORS on POWER PCB2
10 Q3,4,6,7
SWITCHING TRANSISTORS on POWER PCB2
Q4 Collector
Q7 Collector
Q6 Collector
Q3 Collector
D49 & D50 Cathode
Q19 Collector
A series of quick checks can be done to verify Main Power components are not shorted. (Remove the right
side panel to access this area.)
Using a meter set to resistance and with the unitSW1 set to ON position:
1. Measure resistance between MAINS CABLE plug blade terminals 1 & 2 for approx.. 1.6K ohms.
Using a meter set to diode test and with the unit SW1 set to ON position:
2. Place positive meter lead on MAINS CABLE blade terminal 1 and negative meter lead on Bridge Recti-
fier BR1 + terminal. Check for forward bias drop (0.3- 0.7v).
3. Place positive meter lead on BR1(+) terminal and negative meter lead on Q4 terminal. Check for forward
bias drop (0.3- 0.7v).
4. Place negative meter lead on terminal Q4 and positive meter lead on Q7 terminal. Check for forward
biased diode (0.3 – 0.7V)
5. Place negative lead on Q7 Terminal and positive probe on BR2(-) terminal. Check for forward bias diode
(0.3 – 0.7v)
6. Place positive meter led on BR2 (-) terminal and negative meter lead on MAINS CABLE plug blade Line
1. Check for forward bias diode (0.3 – 0.7v)
Содержание EMP 215ic
Страница 6: ...ESAB EMS215C EMP215C 6 DECLARATION OF CONFORMITY Manual 0463 413 001 This Page Intentionally Blank...
Страница 16: ...ESAB EMS215C EMP215C 1 8 SAFETY INSTRUCTIONS Manual 0463 413 001 This Page Intentionally Blank...
Страница 22: ...ESAB EMS215C EMP215C 2 6 INSTALLATION Manual 0463 413 001 208 230V 50A 120V 15A 120V 20A NEMA 6 50P 230VAC plug...
Страница 31: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 OPERATION 3 9...
Страница 38: ...ESAB EMS215IC EMP215IC 4 2 SERVICE INSTRUCTIONS Manual 0463 413 001 This Page Intentionally Blank...
Страница 41: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 3 This Page Intentionally Blank...
Страница 43: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 5 A 12892_AA...
Страница 45: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 7 A 13146_AA...
Страница 78: ...ESAB EMS215IC EMP215IC 6 32 TROUBLESHOOTING Manual 0463 413 001 This Page Intentionally Blank...
Страница 88: ...ESAB EMS215IC EMP215IC 8 8 REPLACEMENT PARTS Manual 0463 413 001 This Page Intentionally Blank...
Страница 95: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 3 A 12892_AA...
Страница 97: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 5 A 13146_AA...
Страница 99: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 7 This Page Intentionally Blank...
Страница 101: ...This Page Intentionally Blank...