S0740 800 186/E080826/P50
-- 24 --
ct34_20
20AP1 Control board
The processor on the control board monitors and controls the various functions of the power
source. The control board is used in combi mode. In combi mode the board handles the
control of the power source, the welding data unit and the MMC panel.
If the circuit board is faulty, it must be replaced. After replacing the circuit board, soft--start
the machine. See the instructions on page 42.
There are two hardware versions of the control board, see page 32.
Note!
The spare part boards have different ordering numbers for the Tig 1500i TA34,
Tig 2200i TA33 and Tig 2200i TA34
,
see the spare parts list.
Circuit board identity
Power source unit
The control board has a machine ID, a hardware ID and a unit type number. To read this
you need the
ESAT
service kit, see page 37.
S
The machine ID defines which type of power source the board is intended for.
S
The hardware ID shows design and type of circuit board.
S
The unit type is used for identification on the CAN bus.
The ID numbers of the power sources are:
Tig 1500i
Tig 2200i
Machine ID = 33
Hardware ID = 4
Unit type = 2
Machine ID = 34
Hardware ID = 4
Unit type = 2
Welding data unit and MMC
The machine ID for the MMC part of the control board determines which type of control
panel that is used. The machine ID can be changed by ESAT.
The ID numbers of the different control panels are:
TA33 machine ID = 37
TA34 machine ID = 19
Hardware ID = 4
Unit type = 0
20AP1:1
Power supply
+5 V and +2.5 V
IC6 monitors the 24 V voltage supply to the 5 V regulator on circuit board
2AP1. IC16 monitors the 5 and 2.
5
V supplies. Regulator VR4 supplies the
processor with +2.
5
V.
Содержание Cadd Tig 1500i TA34
Страница 8: ...S0740 800 186 E080826 P50 8 ct34_00 Tig 1500i with control panel TA34...
Страница 9: ...S0740 800 186 E080826 P50 9 ct34_00...
Страница 10: ...S0740 800 186 E080826 P50 10 ct34_00 Tig 2200i with control panels TA33 and TA34...
Страница 11: ...S0740 800 186 E080826 P50 11 ct34_00...
Страница 19: ...S0740 800 186 E080826 P50 19 ct33_10 10AP1 Component positions WARNING Dangerous voltage mains voltage...
Страница 49: ...S0740 800 186 E080826 P50 49 notes NOTES...