background image

S0740 800 186/E080826/P50

-- 17 --

ct34_02

Power supply board 0487 631--880, used for the Tig 2200i and as spare part

WARNING!

Dangerous voltage - mains voltage.

Содержание Cadd Tig 1500i TA34

Страница 1: ...0740 800 186 Valid for serial no 803 xxx xxxx to 843 xxx xxxx 080826 Caddyt Tig 1500i TA34 Tig 2200i TA33 TA34 Service manual...

Страница 2: ...15AP2 Component positions 23 20AP1 Control board 24 20AP1 1 Power supply 24 20AP1 2 The CAN bus 26 Starting sequence 26 Communication interruptions 26 Terminating resistors 27 20AP1 3 Control panel i...

Страница 3: ...ns without notice INSTRUCTIONS 45 SAFETY 45 INSTALLATION 45 Location 45 Mains power supply 45 OPERATION 46 Connections and control devices 46 Water connection 47 Overheating protection 47 MAINTENANCE...

Страница 4: ...ts are located in the equipment The spare parts list is published as a separate document see page 48 This manual contains details of design changes that have been made up to and including August 2008...

Страница 5: ...ltage 230V 10 1 50 60 Hz Primary current Imax TIG Imax MMA 13 8 A 21 3 A 24 9 A 24 1 A Mains supply Zmax 0 35 ohm Zmax 0 30 ohm No load power 30 W 30 W Setting range TIG MMA 3 150 A 4 150 A 3 220 A 4...

Страница 6: ...ndoor and outdoor use Application class The symbol indicates that the power source is designed for use in areas with increased electrical hazard WIRING DIAGRAM The power source is based on a number of...

Страница 7: ...orrector 15RS1 Shunt 60 mV at 100 A 15ST1 Thermal switch fitted in the winding of main transformer 15TM1 See page 28 15ST2 Thermal switch fitted on the heat sink See page 28 15TM1 Main transformer 20A...

Страница 8: ...S0740 800 186 E080826 P50 8 ct34_00 Tig 1500i with control panel TA34...

Страница 9: ...S0740 800 186 E080826 P50 9 ct34_00...

Страница 10: ...S0740 800 186 E080826 P50 10 ct34_00 Tig 2200i with control panels TA33 and TA34...

Страница 11: ...S0740 800 186 E080826 P50 11 ct34_00...

Страница 12: ...MMC module consists of an operator s control panel and a display board The control panel is used for setting and displaying welding data The welding data are stored by the control board of the power s...

Страница 13: ...i and 0487 631 880 is used for the Tig 2200i The difference between the two versions is the size of inductor L1 Circuit board 0487 631 880 is deliverd as spare part for all machines 2AP1 1 Interferenc...

Страница 14: ...th high rupturing capacity Transistor Q5 is the switching element in a switched voltage supply The secondary voltage 24 V is sensed by IC2 and controlled by IC1 The isolation voltage of transformer T1...

Страница 15: ...V The voltage is controlled by VR3 It has a tolerance of 0 25 V 15 V The voltage is controlled by VR2 It has a tolerance of 0 75 V 13 VB 12V CAN This voltage is unregulated It has a tolerance of 1 5...

Страница 16: ...S0740 800 186 E080826 P50 16 ct34_02 2AP1 Component positions Power supply board 0487 064 884 used for the Tig 1500i WARNING Dangerous voltage mains voltage...

Страница 17: ...S0740 800 186 E080826 P50 17 ct34_02 Power supply board 0487 631 880 used for the Tig 2200i and as spare part WARNING Dangerous voltage mains voltage...

Страница 18: ...F transformer 10TV1 is about 550 V The secondary voltage is about 11 kV if a 4 metre long welding torch is connected If the welding torch is 16 metre long the HF spark is about 8 kV Due to electromagn...

Страница 19: ...S0740 800 186 E080826 P50 19 ct33_10 10AP1 Component positions WARNING Dangerous voltage mains voltage...

Страница 20: ...charging circuit the PFC circuit the gate circuits and the switching circuits The mains rectifier the switching transistors and parts of the charge and PFC circuits are integrated in a semiconductor...

Страница 21: ...river transformer for galvanic isolation of the drive circuits from controller board 20AP1 Switching circuit The switching transistors are integrated in the semiconductor module PM1 Supply to 2AP1 The...

Страница 22: ...ct33_15_1 15AP1 Component positions Pin positions of the semiconductor module Seen from the component side of the board Pin 1 marked P1 starts in the down left corner and continuous anticlockwise aro...

Страница 23: ...the welding current from inductor 15L1 If the diode module has failed a replacement module must be fitted in accordance with the instructions on page 44 Inductor L1 forms an LC circuit with C3 C4 and...

Страница 24: ...ne ID a hardware ID and a unit type number To read this you need the ESAT service kit see page 37 S The machine ID defines which type of power source the board is intended for S The hardware ID shows...

Страница 25: ...Voltage regulator VR2 produces an output voltage of 20 1 0 V which supplies the pulse width modulator output stage Voltage divider R70 R75 supplies 2 6 V to the processor This provides a signal that...

Страница 26: ...ply to the CAN circuits on 20AP1 Starting sequence On power up the board s CAN controller reads in the bus speed from the micro processor 400 kbit s The circuit board displays the starting sequence fr...

Страница 27: ...s of the CAN bus must be terminated by resistive loads Principle diagram of the CAN bus and connecting up of the terminating resistors 20AP1 3 Control panel interface circuits See the service manual f...

Страница 28: ...switches operates the power source is stopped fault code E06 is displayed The power source cannot be restarted until it has cooled sufficiently for the switch es to reclose 20AP1 6 Shunt and current...

Страница 29: ...above 45 V are defined as no welding Output voltage is produced only when TIG welding is in progress If the open circuit voltage arc voltage is above 45 V for more than 100 milliseconds the open circu...

Страница 30: ...al welding mode In the MMA normal welding mode the welding current is briefly increased at the start of welding The peak current phase 1 in the diagram above is engaged for 150 milliseconds The peak c...

Страница 31: ...mp starts if the water lock microswitch is closed 3 Welding starts Stopping welding 1 The welder releases the trigger switch 2 Welding stops 3 The water pump continues to run for a further 6 5 minutes...

Страница 32: ...am above The print number is NOT the same as the ordering number of the board Version 1 of 20AP1 Print numbers up to and including 487343 004 Power sources with serial no 803 xxx xxxx are delivered wi...

Страница 33: ...ults are monitored detected in two ways by test routines that are run on initiation and by functions that can detect a fault when it occurs The control panel displays a unit number to indicate which u...

Страница 34: ...ult persists load new software via ESAT If the fault still persists replace circuit board 20AP1 which carries the memory chip 2 Microprocessor RAM error The microprocessor is unable to read write from...

Страница 35: ...isabled by this fault Action Check that all units are correct connected to the CAN bus See also section 20AP1 2 The CAN bus on pages 26 to 27 16 High open circuit voltage VRD The open circuit voltage...

Страница 36: ...all such items so various means are used to drain off any static discharge from persons to prevent the risk of ESD damage This is done by simple devices wrist straps connected to ground and conductiv...

Страница 37: ...For this a computer program called ESAT ESAB software administration tool is needed The PC is connected to the welding equipment by a cable connector and a CAN reader From the ESAT it is possible to...

Страница 38: ...1 and thyristor TY1 in parallel measure the resistance of R31 It must be 12 ohm on some boards the resistance of R31 is 6 8 or 10 ohm which are also approved values 2 PM1 diode P1D measure between res...

Страница 39: ...terminal L2 The forward voltage drop must be 0 3 to 0 5 V 7 PM1 transistor Q2 measure the resistance between source the positive of capacitor 15C1 and gate pin 19 of the module The resistance must be...

Страница 40: ...are marked on the picture below 4 Bend out the circuit board so that it has no contact with the connections of the diode module 5 Use a multimeter in diode test position to measure the forward voltage...

Страница 41: ...5 from terminal G on control board 20AP1 3 Connect the gate pulse test cable of the SST 3 to terminal G on control board 20AP1 Measuring connection for the gate pulses 4 Switch on the machine 5 Connec...

Страница 42: ...04 red and yellow from circuit boards 2AP1 and 15AP1 see the circuit diagram below Disconnections prior to soft starting 2 Connect the 230 V AC input of the SST 3 to terminals B2 and B4 on circuit boa...

Страница 43: ...10 Switch on the machine and set it to MMA mode 11 Check that the DC voltage across smoothing capacitor 15C1 is 22 24 V 12 Check that the DC voltage at the welding terminals is about 6 7 V 13 If all t...

Страница 44: ...o a torque of 2 5 Nm and then further tighten them to 4 5 Nm 3 Tighten the screws that connect transformer 15TM1 and capacitor 15C1 to circuit board 15AP1 to a torque of 4 5 Nm CAUTION Incorrectly fit...

Страница 45: ...ent drawn from the mains supply influence the power quality of the grid Therefore connection restrictions or requirements regarding the maximum permissible mains impedance or the required minimum supp...

Страница 46: ...OPERATION General safety regulations for the handling of the equipment can be found in the instruction manual Read through before you start using the equipment Connections and control devices 1 Conne...

Страница 47: ...ety plates to connect or carry out service maintenance or repair work on welding equipment Note All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in...

Страница 48: ...ermal cut outs have tripped S Check the mains power supply fuses The thermal cut out trips frequently S Make sure that you are not exceeding the rated data for the welding power source i e that the un...

Страница 49: ...S0740 800 186 E080826 P50 49 notes NOTES...

Страница 50: ...92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aires...