- 71 -
5.1
ERROR CODES
NOTES:
27 Potentiometer,
welding current I2
Sets the welding current. The welding current can be set during
no-load operation and is shown in the 7 segment display.
28 LED,
welding current I2
LED illuminates, when the welding current I2 is active. During
pulsed operation: Toggles between the displays I2 and I4 with
fixed pulse frequency.
29 Potentiometer,
pulse time I4
Sets the pulse time of the current I4.
30 Potentiometer,
final current I3
Sets the final current I3.
Select a value so that no craters are caused.
Error Possible
cause
Action
1 Primary
overcurrent
Fault in power supply
Call service
2 Primary
undervoltage Faulty power supply
Faulty fuses
Check power supply
Generator is underdimensioned Use generator with sufficient
power
3 Primary
overvoltage
The voltage used does not
comply with the rated voltage
Check power supply
4 Overtemperature
in-
let/ outlet vents
blocked
Exceeded allowed duty cycle
Let device cool while running
Check air supply
Ambient temperature too high
Let device cool while running
5
Cooling water distur-
bance
No water in cooling device
Refill (Remember antifreeze!)
Defective or calcified switch
Install a new switch
Water pump defective
Install a new pump
Содержание Aristotig 405 AC/DC
Страница 1: ...0458 165 002 9910 DTG 405 Aristotig 405 AC DC Welding rectifier Service manual...
Страница 9: ...9 NOTES...
Страница 10: ...10 CONNECTION DIAGRAM DTG 405...
Страница 11: ...11...
Страница 15: ...15 NOTES...
Страница 16: ...16 BLOCK DIAGRAM DTG 405 405a pcx...
Страница 17: ...17 Warning Some parts of this circuit are connected to mains voltage potential 405b pcx...
Страница 27: ...27 A2 COMPONENT POSITIONS a2 1b pcx a2 2b pcx...
Страница 30: ...30 A4 A11 COMPONENT POSITIONS Warning The circuit and its parts are connected to mains voltage potential...
Страница 40: ...40 A9 A13 COMPONENT POSITIONS A10 A14 COMPONENT POSITIONS...
Страница 57: ...57 209 201 212 203 204 205 206 207 208 D04 0301 1 214 215 216 218 217 219 220 110 221 222 213 202...
Страница 62: ...62 8 WAVEFORM AC2 SMOOTH WAVE ac2 pcx...
Страница 67: ...67 LOAD CHARACTERISTICS NOTES 0 10 20 30 40 50 60 70 80 90 0 50 100 150 200 250 300 350 400 A V TIG MMA DTG 405...
Страница 81: ...81 NOTES...
Страница 86: ...86 D04 0304 1 D04 0305 0 501 502 503 502 502 504 505 506 507 508 509 510 511 512 513 515 516 505 517...
Страница 91: ...page...