4 INSTALLATION
0459 087 687
- 11 -
© ESAB AB 2017
Check that the unit is connected to the correct mains power supply
voltage, and that it is protected by the correct fuse sizes. A protective
earth connection must be made, in accordance with regulations.
Rating plate with supply connection data
Recommended fuse sizes and minimum cable areas
Mig U5000i
460 V 3~ 60 Hz
Mains voltage
460 V
Mains cable area, CU/AWG (mm
2
)
10(6)
Phase current, I RMS
24 A
Fuse, Time Delay
25 A
NOTE!
Sizes per National Electric Code for 90 °C rated copper conductors @ 30 °C
ambient. Not more than three conductors in raceway or cable. Local codes
should be followed if they specify larger sizes other than those listed above.
4.4
Terminating resistor
In order to avoid communication interference, the ends of the
CAN bus must be fitted with terminating resistors.
One end of the CAN bus is at the control panel, which has an
integral terminating resistor. The other end at the power
source must be fitted with the terminating resistor, as shown
on the right.
4.5
Connection of multiple wire feed units
With control unit and wire feed units without control panel (M0) it is possible to manage up to
4 wire feed units from one power source.
It is possible to choose between the following connections:
•
1 GTAW (TIG) torch and 1 GMAW (MIG/MAG) gun (Universal power source required)
•
2 GMAW (MIG/MAG) guns
•
1 GTAW (TIG) torch and 3 GMAW (MIG/MAG) guns (Universal power source required)
•
4 GMAW (MIG/MAG) guns
When welding with water-cooled GMAW guns on all wire feed units, it is recommended to
connect a separate cooling unit for the two extra guns.
We recommend connecting the guns in parallel.