5 OPERATION
0463 280 201
- 12 -
© ESAB AB 2014
FeedControl 3004HW
Shows serial no. 325-xxx-xxxx:
Shows serial no. 410-xxx-xxxx:
1.
White indicating lamp – Power supply ON
9.
Rating plate
2.
Connection from electronic unit to drive
unit - pulse signal encoder
10.
Connection for terminating resistor or
forwarding to next wire feed unit
3.
Connection from electronic unit to drive
unit - 42V power
11.
Connection for control cable from power
source
4.
Connection for spatter removal air, out
12.
Connection for shielding gas, in
5.
Connection for coolant to welding torch,
BLUE
13.
Connection for spatter removal air, in
6.
Connection for welding current from drive
unit (OKC)
14.
Connection for coolant from power source
(cooling unit), BLUE
7.
Connection for coolant from welding torch,
RED
15.
Connection for welding current from power
source (OKC)
8.
Connection for shielding gas, out
16.
Connection for coolant to power source
(cooling unit), RED
Symbol and function explanations
Inlet spatter removal air
Shielding gas
Outlet spatter removal air
Used for spray-cleaning the contact tip on the welding torch.
Gas purging
Gas purging is used when measuring the gas flow or to flush any air or moisture
from the gas hoses before welding starts. Gas purging occurs for as long as the
button is held depressed and occurs without voltage or wire feed starting.