© ESAB AB 2003
- 15 -
bu20d1ea
7
FAULT TRACING
Try these recommended checks and inspections before sending for an authorised
service technician.
Type of fault
Action
No arc.
S
Check that the mains power supply switch is
turned on.
S
Check that the welding current supply and
return cables are correctly connected.
S
Check that the correct current value is set.
Welding current is interrupted during welding
S
Check whether the thermal overload trips
have operated (indicated by the orange
lamp on the front panel).
S
Check the main power supply fuses.
The thermal overload trips operate frequently.
S
Check to see whether the air filters are
clogged.
S
Make sure that you are not exceeding the
rated data for the power source (i.e. that the
unit is not being overloaded).
Poor welding performance.
S
Check that the welding current supply and
return cables are correctly connected.
S
Check that the correct current value is set.
S
Check that the correct electrodes are being
used.
S
Check the main power supply fuses.
8
ORDERING OF SPARE PARTS
Mig U4000i is designed and tested in accordance with the international an European
standards IEC/EN EN 60974-1 /-2 /-3 and EN EN 60974-10.
It is the obligation of the service unit which has carried out the service or repair work
to make sure that the product still conforms to the said standard.
Repair and electrical work should be performed by an authorised ESAB service
technician. Use only ESAB original spare and wear parts.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.