background image

For contact information visit esab.com

ESAB AB, Lindholmsallén 9, Box 8004, 402 77 Gothenburg, Sweden, Phone +46 (0) 31 50 90 00

http://manuals.esab.com

Содержание Aristo Mig C3000i

Страница 1: ...Aristo Origo Instruction manual 0459 825 301 GB 20180918 Valid for serial no 039 209 xxx xxxx Mig C3000i...

Страница 2: ......

Страница 3: ...power supply 10 5 OPERATION 12 5 1 Connections and control devices 14 5 2 Fan control 14 5 3 Overheating protection 14 5 4 Welding without gas 15 5 5 Wire feed pressure 15 5 6 Replacing and inserting...

Страница 4: ...y precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All w...

Страница 5: ...ELECTRIC AND MAGNETIC FIELDS Can be dangerous to health Welders having pacemakers should consult their physician before welding EMF may interfere with some pacemakers Exposure to EMF may have other he...

Страница 6: ...uipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic...

Страница 7: ...for the welding power source Instruction manual in english for the control panel Decal with recommended wear parts 5 metre return cable 2 2 Control panel The welding power source is supplied with one...

Страница 8: ...le load at MIG MAG 35 duty cycle 300 A 29 V 60 duty cycle 240 A 26 V 100 duty cycle 200 A 24 V Permissible load at MMA 30 duty cycle 300 A 32 V 60 duty cycle 230 A 29 2 V 100 duty cycle 190 A 27 6 V P...

Страница 9: ...VRD specification on the rating plate The VRD function is explained in the instructions for the control panel if the panel has that function 3 Valid for a power source controlled from a U6 control pan...

Страница 10: ...h the distribution network operator if necessary that the equipment is connected only to a supply with a short circuit power greater than or equal to Sscmin Refer to the technical data in the TECHNICA...

Страница 11: ...16 A 16 A NOTE The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations For other regions supply cables must be suitable for the application and meet local and n...

Страница 12: ...sportation Never pull the equipment by the welding torch WARNING Assure that the side panels are closed during operation WARNING To prevent the reel from sliding off the hub Lock the reel in place by...

Страница 13: ...5 OPERATION 0459 825 301 13 ESAB AB 2018...

Страница 14: ...source has a time control that means that the fans continue to run for 6 5 minutes after welding has stopped and the unit switches to energy saving mode The fans start again when welding restarts The...

Страница 15: ...protective cover Close the side panel Move the return cable from the negative outlet to the positive outlet 5 5 Wire feed pressure Start by making sure that the wire moves smoothly through the wire g...

Страница 16: ...t nozzle and the wire guide Secure the pressure sensor Close the side panel 5 7 Changing feed rollers Open the side panel Disconnect the pressure sensor 1 by folding it backwards the pressure rollers...

Страница 17: ...therwise result in overheating Wire feed unit Check regularly that the wire feed unit is not clogged with dirt Cleaning and replacement of the wire feed unit mechanism s worn parts should take place a...

Страница 18: ...lding current is interrupted during welding Check whether the overheating protection has operated fault code E6 is displayed on the control panel Check the mains power supply fuses The overheating pro...

Страница 19: ...n standards IEC EN 60974 1 IEC EN 60974 5 and IEC EN 60974 10 Class A It is the obligation of the service unit which has carried out the service or repair work to make sure that the product still conf...

Страница 20: ...DIAGRAM 0459 825 301 20 ESAB AB 2018 DIAGRAM...

Страница 21: ...DIAGRAM 0459 825 301 21 ESAB AB 2018...

Страница 22: ...02 Spare parts list Mig C3000i 0460 454 xxx Instruction manual Control panel Origo MA23 and Origo MA24 0459 839 024 Spare parts list Control panel Origo MA23 and Origo MA24 0459 287 xxx Instruction ma...

Страница 23: ...red 0 9 1 0 1 2 mm V 0 9 1 0 S2 1 2 S2 0458 825 001 Feed pressure rollers Cored 0 9 1 0 1 2 mm V Knurled 1 0 R2 1 2 R2 0458 824 001 Feed pressure rollers Al 0 8 0 9 1 0 mm U 0 8 A2 1 0 A2 0458 824 002...

Страница 24: ...WEAR PARTS 0459 825 301 24 ESAB AB 2018...

Страница 25: ...ote control unit MTA1 CAN MIG MAG wire feed speed and voltage MMA current and arc force TIG current pulse and background current 0459 491 882 Remote control unit M1 10Prog CAN Choice of one of 10 prog...

Страница 26: ...SF 315 CLD 0468 410 885 0468 410 886 315 A 60 285 A 60 0 8 1 2 PSF 405 0458 401 882 0458 401 883 380 A 60 325 A 60 0 8 1 6 PSF 405 C 0458 499 882 0458 499 883 380 A 60 325 A 60 1 0 1 6 PSF 405 RS3 045...

Страница 27: ...ACCESSORIES 0459 825 301 27 ESAB AB 2018...

Страница 28: ...For contact information visit esab com ESAB AB Lindholmsall n 9 Box 8004 402 77 Gothenburg Sweden Phone 46 0 31 50 90 00 http manuals esab com...

Отзывы: