3 TECHNICAL DATA
0459 293 787
- 15 -
© ESAB AB 2018
Mig 5000i
Mig 5000i WeldCloud™
GMAW (MIG/MAG), SMAW
(MMA), VRD function
deactivated
2)
59 V
59 V
VRD function activated
2)
< 35 V
< 35 V
Operating temperature
14 to 104 °F
(-10 to +40 °C)
14 to 104 °F
(-10 to +40 °C)
Transport temperature
-4 to 131 °F
(-20 to +55 °C)
-4 to 131 °F
(-20 to +55 °C)
Dimensions l × w × h
without cooling unit
with cooling unit
24.6 × 15.5 × 19.5 in.
(625 × 394 × 496 mm)
24.6 × 15.5 × 19.5 in.
(625 × 394 × 496 mm)
24.6 × 15.5 × 30.6 in.
(625 × 394 × 776 mm)
24.6 × 15.5 × 30.6 in.
(625 × 394 × 776 mm)
Continual A-weighted
sound pressure
<70 db
<70 db
Weight
without cooling unit
with cooling unit
150 lb (68 kg)
174 lb (79 kg)
194 lb (88 kg)
218 lb (99 kg)
Insulation class
transformer H
H
Enclosure class
IP23
IP23
Application class
1)
Valid for power sources without VRD specification on the rating plate.
2)
Valid for power sources with VRD specification on the rating plate. The VRD function is
explained in the instruction manuals for the control panel, if the panel has that function.
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading. The duty cycle is valid for 40 °C / 104 °F, or below.
Enclosure class
The
IP
code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked
IP23
is intended for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
Содержание Aristo Mig 5000i
Страница 2: ......
Страница 3: ......
Страница 23: ...DIAGRAM 0459 293 787 23 ESAB AB 2018 DIAGRAM...