-- 13 --
cra1d1ea
ACCESSORY SET FOR EXTERNAL FILLET WELDING
Order number, see on page 5.
Fitting:
1. Dismount the spacer tube.
2. Rotate the inner portion, so that the cable is just opposite the group of holes
2xø8 in the envelope.
3. Insert a 2.5 mm Allen key through the holes ø8 and slacken the welding cable clamp
(approx. 6 turns).
4. Dismount the electrode holder and pull it out.
5. Replace the electrode holder and pull into correct position by means of the welding cable.
6.
TIGHTEN THE WELDING CABLE CLAMP THROUGH THE HOLES ø8.
OTHERWISE THE ROTATION MOTOR WILL BE DAMAGED!
7. Fit the guide finger mount, the guide fingers, then Allen screw and the locking washer.
8. Replace the electrode nozzle.
cra1b014