Figure 3-2. Input Terminal Board Configuration for 230/460/575 Model
(factory supplied in the 575 configuration)
230 Vac Input
460 Vac Input
575 Vac Input
Figure 3-3. Input Terminal Board Configura-
tion 230/460 Model (factory supplied in the
460 configuration)
460 Vac Input
230 Vac Input
Figure 3-4. Input Terminal Board Configura-
tion 220/400 Model (factory supplied in the
400 configuration)
220 Vac Input
400 Vac Input
*
*
*
SECTION 3
INSTALLATION
E. Figures 3-2, 3-3 & 3-4 illustrate the input voltage terminal board and the input voltage link connections. The particular
voltages from which this power source may be operated are stated on the rating plate. The voltage links were factory
set for highest voltage stated on the rating plate. If the power source is to be operated on another stated input voltage,
the links must be reset for that particular input voltage. Always verify the input voltage and check the link arrangement
regardless of factory setting. The voltage links are set up by reconfiguring the copper link bars to the voltage designa-
tions for the desired voltage.
Содержание 653 cvcc
Страница 4: ...4 TABLE OF CONTENTS...
Страница 20: ...20 SECTION 2 DESCRIPTION...
Страница 28: ...28 SECTION 3 INSTALLATION...
Страница 40: ...40 SECTION 7 REPLACEMENT PARTS 653cvcc Front Panel View 195...
Страница 41: ...41 SECTION 7 REPLACEMENT PARTS 653cvcc Front Isometric View...
Страница 42: ...42 SECTION 7 REPLACEMENT PARTS 653cvcc Internal View...
Страница 43: ...43 SECTION 7 REPLACEMENT PARTS 653cvcc Rear Isometric View...
Страница 44: ...44 SECTION 7 REPLACEMENT PARTS 653cvcc Internal View...
Страница 45: ...45 SECTION 7 REPLACEMENT PARTS 653cvcc Top Internal View...
Страница 49: ...49 SECTION 7 REPLACEMENT PARTS...
Страница 50: ...50 NOTES...
Страница 53: ......
Страница 54: ......