7 FAULT TRACING
0463 283 001
- 19 -
© ESAB AB 2013
7
FAULT TRACING
Try these recommended checks and inspections before sending for an authorised service
technican.
Type of fault
Actions
No arc.
•
Check that the mains power supply switch
is turned on.
•
Check that the welding current supply and
return cables are correctly connected.
•
Check that the correct current value is
set.
Welding current is interrupted during welding •
Check whether the thermal overload trip
has operated (indicated by the orange
lamp on the front)
•
Check the main power supply fuses.
The thermal overload trips operate frequently •
Check to see whether the air filters are
clogged.
•
Make sure that you are not exceeding the
rated data for the power source (i.e. that
the unit is not being overloaded).
Poor welding performance.
•
Check that the welding current supply and
return cables are correctly connected.
•
Check that the correct current value is
set.
•
Check that the correct welding wires are
being used.
•
Check the main power supply fuses.
Содержание 0465 152 880
Страница 1: ...Origo Instruction manual 0463 283 001 GB 20131029 Valid for 145 xxx xxxx Mig 4004i A44...
Страница 2: ......
Страница 21: ...DIAGRAM 0463 283 001 21 ESAB AB 2013 DIAGRAM...