10
Complete programming chart
D1
D2
Parameter
D3
D4
Default
option
Options or values
C
1
Motor turning direction
0
1
x
0
2
4
Opening safety device (photocell or strip)
0
0
x
Device not installed
1
0
Device without testing
1
1
Device with testing
5
Closing safety device (photocell or strip)
Closing photocell with
C520
or
C521
, also
prevents the gate from opening
0
0
x
Device not installed
1
0
Device without testing
1
1
Device with testing
2
0
Device without testing
2
1
Device with testing
8
Radio receiver
0
1
RSD card (non-decoding)
0
2
x
Twin-channel decoding card
P
1
Total opening radio code programming
o
ç
2
Pedestrian opening radio code programming
o
ç
3
Gate open/close programming
o
ç
F
1
Functioning mode
0
1
Automatic
0
2
x
Step-by-step
2
Standby in automatic mode
0
...
5ÿ
0
...
9
15
59
= 59 sec;
2ÿ5
= 2 min. 50 sec., etc
3
Pedestrian opening
0
0
x
Pedestrian opening is not carried out
1
0
10% of total opening
2
0
20% of total opening
3
0
30% of total opening
4
0
40% of total opening
5
0
50% of total opening
A
0
Flashing light
0
1
x
No pre-warning
0
2
With pre-warning
1
Garage light time
0
...
5ÿ
0
...
9
03
59
= 59 sec;
2ÿ5
= 2 min. 50 sec., etc
2
Gate speed
0
1
...
5
05
01
: minimum speed;
05
: maximum speed
3
Slowdown speed
0
1
...
3
01
01
: minimum speed;
05
: maximum speed
4
Slowdown distance
0
0
...
5
01
00
: minimum distance;
05
: maximum distance
5
Reverse after closing (to offset the expansion
of the gate)
A50x
: stops in selected position without
making contact
A51x
: makes contact and reverses back to
the selected position
0
...
1
1
...
9
05
x1
: no recede;
x9
: maximum recede
6
Maximum thrust
0
...
1
0
...
9
05
01
: minimum thrust;
10
: maximum thrust
7
Closing
photocell
used during standby (in
automatic mode only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
8
Pushbutton
operation during standby (in
automatic mode only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
9
Opening mode
0
1
x
Opening in accordance with the mode
selected in the main functions (
F
)
0
2
Collective opening
(the control board
does not obey the key commands during
opening)
0
3
Step-by-step opening
(the gate halts if a
key device is activated during opening.
The gate closes when operated again)
ç
1
Operations carried out
X
X
I n d i c a t e s t h e h u n d r e d s o f c y c l e s
completed (for example,
68
indicates
6,800 cycles completed
)