7
T H E S M A R T L I V I N G
8 - MODE PULSE/ STEP
Each relay can be set in pulse or step mode according to the set-up of the dip-switch S1 as shown on the following
tab. 2. In step ( or bistable ) mode the led corresponding to the relay activated blinks.
With the following procedure it’s possible to calculate the number of transmitters memorized.
The display is carried out by the led R3 ( Red) and R4 ( Green).
Push P1 and verify that R1 switches on. Keep on pushed P1 until R1 switches off and than release it.
At this point starts a sequence of flashes of the 2 leds R3 (RED) ed R4 (GREEN)
The sequence is the binary expression of the transmitter keys memorized.
The final number can be calculated making reference to the following table:
9 - DISPLAY OF THE MEMORY SPACE
Led on
1°
2°
3°
4°
5°
6°
7°
Green led value
1
2
4
8
16
32
64
Red led value
0
0
0
0
0
0
0
Tab.3
Example 4
:
Sequence :
LR, LR, LV, LV, LR, LR, LR.
Final number:
0 + 0 + 4 + 8 + 0 + 0 + 0 = 12
Therefore in the memory are memorized 12 transmitter keys.
ON
OFF
R1 R2
R3
R4
DIP-SWITCH S1
RELAY1
RELAY2
RELAY3
RELAY4
ON
OFF
BISTABLE
BISTABLE
BISTABLE
BISTABLE
PULSE
PULSE
PULSE
PULSE
Tab.2