5

 6 - REMOTE CONTROLS MEMORIZATION

The memorization of the remote controls can be carried on in sequential way, by using only P1. 
Each step is confirmed by the led  R1, R2, R3, R4.

The procedure consists in a sequence of pressures of P1 
 The lighting of the leds R1, R2, R3, R4 is cyclic: at each pressure of P1 a led is turned on and the preceding led is turned 
off. (fig. 2)
The led light is stable or blinking according to the setting of the corresponding dip-switch. ( see. cap. 8 )

Fig. 2

R1

R2

R3

R4

6.1

The relay configuration ( pulse or step ) is displayed by the led light 

LED with stable light : 

PULSE Relay

LED with blinking light : 

BISTABLE or STEP Relay

Relay condition

6.2 4 keys remote memorization 

The memorization consists in a sequence of pressures of P1

Example 2

: 4 keys remote memorization with the following links:  

Key A --> Relay 1, Key B --> Relay 2, Key C --> Relay 3, Key D --> Relay 4.

T H E S M A R T L I V I N G

Keep P1 pushed for 2 
sec. until LD1 
switches on

R1 lits

Release

P1

Push key A of the 

transmitter to 

memorize

Press P1

Push key B of the 

transmitter to 

memorize

Release

P1

R2 lits

R1 switches off 

and on again

R3 lits

Release

P1

Push key C of the 

transmitter to 

memorize

Push P1

Push key D of the 

transmitter to 

memorize

Release

P1

R4 lits

R4 switches off and on 

and after 2 sec. 

switches off 

Press

P1

Fig. 3

R2 

and on again

switches off 

R3 

and on again

switches off 

Содержание SEL2641R433-BD4

Страница 1: ...ERONE DIN GUIDE 4 RELAY RECEIVER USE AND INSTALLATION MANUAL SEL2641R433 BD4 THE SMART LIVING...

Страница 2: ...s are NO NC The operating mode of the relays can be pulse or step with dip switch selection The memorization of the remote controls can be carried on in self learning The transmitter security codes ar...

Страница 3: ...3 K4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Relay outputs map Relay Terminal Contact Relay 1 13 NO Relay 3 19 NO Relay 1 14 C Relay 3 20 C Relay 1 15 NC Relay 3 21 NC Relay 2 1...

Страница 4: ...auxiliary push buttons fot the direct activation of the relays The push buttons PR1 PR2 PR3 PR4 on fig 1 not provided act on the relays like the remote controls keys in pulse or step mode according t...

Страница 5: ...light PULSE Relay LED with blinking light BISTABLE or STEP Relay Relay condition 6 2 4 keys remote memorization The memorization consists in a sequence of pressures of P1 Example 2 4 keys remote memor...

Страница 6: ...witch and then switch off definitively To cancel more keys of the same transmitter B C D it s necessary to wait for the R1 switching off and repeat the procedure from the beginning Example 3 Erasure o...

Страница 7: ...ntil R1 switches off and than release it At this point starts a sequence of flashes of the 2 leds R3 RED ed R4 GREEN The sequence is the binary expression of the transmitter keys memorized The final n...

Страница 8: ...455628 Web www erone com email info erone com NOTE Guarantee period 24 months from the productions date placed inside In this period if the appliance has any malfunction due to a defective component...

Отзывы: