Erone 024A Series Скачать руководство пользователя страница 9

Push PR and keep it pressed down until the led LR switches on. 
Then push simultaneously PR and PV until both the leds LR and LV 
start to blink.
in this way all the codes present in the memory will be erased.

General command

Push and keep pushed the button PV of the receiver until the green 
led LV switches on;
Within 4 seconds push the key D of the transmitter to memorise.
The green led LV will switches off and the motor relay will activate 
for a while.
The D key will make the closing of the motor.
The activation of the remaining transmitter keys is automatic, by 
correlating the key B to the opening and the key C to the stop.

8 - CONDOMINIUM MANAGING

For the managing of the codes it is previously neccary to annotate the 
memory locations of each transmitter code and to wich relay it is 
correlated.
The transmitter codes management is usefull when it is necessary to 
store many codes into the receiver, for a condominium installation 
(ex. 100 transmitters into 100 memory locations).

Operating description

The  position  of  the  code  in  the  memory  is  displayed  by  a  binary 
sequence of 7 bit.
In  order  to  calculate  the  right  position  of  the  code  refer  to  the 
following  table:  by  making  attention  to  the  flash  sequence  of  the 
green led LV:

7 bit code        1     2     3    4     5     6    7

LV

association     1    2     4     8    16  32  64

It is enough to take into count only the flashes of the green 
led because the value of the ones of red led have always 
value 0.

EXAMPLE

  :  Led  sequence  correspondent  to  the  37th 

positions of the memory:

1st  flash: 

green led 

2nd  flash:  red led 
3rd  flash:   green led
4th  flash:   red led 
5th  flash:  red led  
6th  flash:  green led 
7th  flash:  red led 

  1    2    3    4    5     6    7

  1    2    4    8   16   32  64

1 + 0 + 4 + 0 + 0 + 32 + 0 = 37

Check of the number of stored transmitters

On the receiver, enter in programming mode by pushing PR until LR 
switches  ON.
Release PR and push againg PR for one second.
From  now  on,  a  sequence  of  led  flashes  commences,  showing  a 
number which can be calculated by following the previous table.
The final number is equal to the total number of codes stored in the 
memory.

Check of the transmitter position inside the memory.

Push and release the transmitter button for which it is necessary the 
check.
Push PR for 1 second: from this time on, a led flash sequence starts.
By decoding the message, as explained above, it is possible to get the 
information of the code position.

Replacement of the code of a stored transmitter

It is possible to delete a stored transmitter code and replace it with 
another one, in the same memory position.
For this operation it is necessary to know exactly the memory position 
of the transmitter to replace.
See  the  previous  chapter  titled  "Check  of  the  transmitter  position 
inside the memory".
Once known the memory position of the transmitter which has to be 
replaced, follow the next procedure:

- On the receiver push and keep pushed PR until the led LR is ON.
Push PV for at least 1 second.
- Start the binary sequence by pushing PR or PV in order to get the 
position of the memory cell to replace.

Example of a new transmitter positioning on the 42th cell of memory:

LR   LV   LR   LV   LR   LV   LR 

0    2     0     8    0   32   0
0 + 2 + 0 + 8 +0 + 32 +0 = 42

Push in sequence:

PR, PV, PR, PV, PR, PV, PR.

Fom  now  on  the  red  led  LR  lights  on  showing  the  start  of  the 
programmation phase.
Store the new transmitter code by pushing on the desired transmitter 
button (A, B, C or D).
At the end the red led turn off, by giving the acknowledge of the 
successful procedure.
In this way the old code has been deleted and the new one has been 
stored in the same memory position and will activate the relay.

- it is possible to use always the same transmitter (i. e. the installation 
maintenance transmitter) for the user code removal.

Memory full

When the memory is full (that means that the 85 or 100 memory 
cells have been stored, depending upon the used model and a 
memorisation phase is commenced) the receiver led LR and LV 
blink 3 times simultaneously.
Then the led corresponding to the excited relay remains on and so 
it is still possible to perform the other functionalities described in 
the previous chapters.

!

It is necessary to have a 4 key transmitter of 
the same range

7 - MEMORY ERASURE

Pag. 9

Содержание 024A Series

Страница 1: ...Radioprogrammer 750W R cepteur s quentiel 750W Funkmotorsteuerung 750W Manuale d installazione ed uso Italiano Pag 4 Use and installation Manual English Pag 7 Notices d installation et utilisation Fra...

Страница 2: ...nible l adresse internet suivante www erone com Declaration of Conformity Der hersteller CDVI Wireless Spa behauptet dass das funkger t entsprechend der vorschrift 2014 53 UE ist Die komplete beschrei...

Страница 3: ...i I O Terminal boards Bornes Anschl sse Led L2 Contatto NA esterno Led L2 NO external command Led L2 Contact NO exterieur Led L2 Sicherheitsvorrichtung 52 140 115 128 104 Tasto PR LR Push button PR LE...

Страница 4: ...one 230 Vac Potenza massima del motore 750 W Uscita ausiliaria 24 Vac 200 mA Capacit di memoria 100 Temperatura di funzionamento 20 70 C Grado di protezione IP44 Peso 380 gr Dimensioni 140 x 115 x 52...

Страница 5: ...cessitano di un solo pulsante del trasmettitore per aprire chiudere e fermare Il comando locale prioritario sul comando generale Comando generale E necessario disporre di un trasmettitore a 4 canali d...

Страница 6: ...i corrispondenza indica la quantit di trasmettitori memorizzati Verifica della posizione di un codice trasmettitore in memoria Premere sul pulsante del radiocomando che si desidera controllare e rilas...

Страница 7: ...maximum power 750 W Auxiliary output 24 Vac 200 mA Memory capacity 100 Operating temperature 20 70 C IP grade IP44 Weight 380 gr Overall dimensions 140 x 115 x 52 mm 2 TECHNICAL SPECIFICATIONS 4 INSTA...

Страница 8: ...14 Local command Push and keep pushed the button PR of the reciver until the red led switches on Within 4 seconds push the key of the transmitter to memorise The red led LR will switch off Repeat the...

Страница 9: ...The final number is equal to the total number of codes stored in the memory Check of the transmitter position inside the memory Push and release the transmitter button for which it is necessary the ch...

Страница 10: ...P44 Poids 380 gr Dimensions mm 140 x 115 x 52 3 FONCTIONNEMENTS S quentiel 1 impulsion provoque l ouverture 1 impulsion provoque la fermeture arr t sur temporisation ou impulsion Mixte 1 impulsion pro...

Страница 11: ...iller en mode s quentiel et n cessite trois touches d metteurs une touche canal B pour l ouverture une touche canal D pour la fermeture et un touche canal C pour l arr t En cours de travail ouverture...

Страница 12: ...pas de contr ler si un code a t m moris plus d une fois En cons quence il faut consid rer que si un metteur est enregistr deux fois ou plus il est n cessaire de le remplacer dans toutes les positions...

Страница 13: ...5 x 52 mm Daten SEL39R30 P7 Empf ngertyp Frequenz 433 92 MHz Frequenz des lokalen Oszillators 6 6128 MHz Modulation AM ASK Eingangsimpadanz 50 Ohm Zwischenfrequenz 10 7 MHz Empfindlichkeit f r erfolgr...

Страница 14: ...lter 2 ON 12 Sek Dip Schalter 3 ON 24 Sek Dip Schalter 4 ON 48 Sek Dip Schalter 5 ON 96 Sek Befehlsauswahl lokaler Befehl Die Sendertasten werden mit der Taste PR eingelernt f r die Funktionen sequent...

Страница 15: ...er Bin rsequenz berschreiben eines eingelernten Handsenders nur Modell 2641 R433P7 Ein verlorener oder defekter Handsender kann direkt durch berschreiben seiner Speicherposition gel scht und durch ein...

Страница 16: ...vom inneren angezeigten Herstellungsdatum W hrend solcher Periode wenn das Ger t nicht korrekt wegen eines defekten Bauelements arbeitet wird es beseitigt oder nach Hersteller Entscheidung ersetzt Die...

Отзывы: