ENGLISH
The receiver ERONE 750 W is a radio programmer which can
drive directly an asynchronous 230 Vac AC motor with max power
of 750 W. The operating frequency and the coding system are
different, depending upon the model.
The following table summarises the range of Erone radio
programmers, pointing out series, frequency and coding system:
SERIES
TYPE
FREQUENCY
CODING
ERONE 024A
SEL 2641R433P7
433.92 MHz
Rolling code
ERONE 30(DP/SL) SEL 39R30P7
30.875 MHz
Dip/Self learning
ERONE DS433
SEL 39R433P7
433.92 MHz
Dip-switch
Depending upon the frequency and the coding, the receiver
operates with different transmitters ERONE, according to the
following table:
Receiver Type
Usable transmitter
SEL 2641 R433P7
S2TR2641E2/E4
SETR2641AM2
SETR2641-TM
SEL 39 R433P7
SETDS39433 E2/E4
SEL39 R30P7
SETL 39E2/E4
SETD 39E2/E4
1 - INTRODUCTION
Type
SEL 2641R433-P7 / SEL39R433-P7
Receiver type
Carrier frequency
433,92 MHz
Local oscillator frequency
6,6128 MHz
Modulation
AM/ASK
Input load
50 Ohm
Intermediate frequency
10,7 MHz
Input sensitivity
-115 dBm
Local oscillator emissions
< -57 dBm
Power voltage
230 Vac
Motor maximum power
750 W
Auxiliary output
24 Vac / 200 mA
Memory capacity
85 / 100
Operating temperature
-20°
÷
+70°C
IP grade
IP44
Weight
380 gr.
Overall dimensions
140 x 115 x 52 mm
Superheterodyne
Type
SEL39R30-P4
Receiver type
Superheterodyne
Carrier frequency
30,875 MHz
Local oscillator frequency
30,420 KHz
Modulation
AM/ASK
Input load
50 Ohm
Intermediate frequency
455 KHz
Input sensitivity
-115 dBm
Local oscillator emissions
< -57 dBm
Power voltage
230 Vac
Motor maximum power
750 W
Auxiliary output
24 Vac / 200 mA
Memory capacity
100
Operating temperature
-20°
÷
+70°C
IP grade
IP44
Weight
380 gr.
Overall dimensions
140 x 115 x 52 mm
2 - TECHNICAL SPECIFICATIONS
4 - INSTALLATION
3 - FUNCTIONALITY
Sequential (or cyclic):
1 Pulse opens
1 Pulse closes, stop with a timer
Mixed
1 Pulse opens, closing only with permanent contact.
Man present:
Opening and closing only with permanent contact (reduced
range). The motor time-out is selectable (from 6 to 186 sec) by
means of 5 dip - switches; it is used as security to avoid powering
the motor for too long after the mechanical stop.
Other features:
Local and general operating selection (with multiple motor
driving); the general command is possible only for the sequential
operating mode.
For the general mode using it is necessary to use a 4 keys
transmitter of the same range.
It possible to connect an external push button or a key - contact to
complete the radiocontrol.
The memory capacity is 85 or 100 transmitters.
Positioning
The local choice is very impotant for the best result of the installation.
The following conditions have to be followed:
- Fix the radioprogrammer far from the interference sources as
informatic systems, alarm systems or other radio emissions.
- The distance between 2 receivers should be greater of 1.5 mt.
Fixing
Remove the cover of the receiver; fix the box in each corner by
using the screws and the plugs supplied.
Connections
1
- Connect the power supply (230 Vac) to the terminal blocks (fig.
10):
terminal 1 = PH phase
terminal 2 = N neutral
terminal 6 = earth
Ph
1
2
6
N
3
4
5
7
C
O CL
Fig. 11
Fig.10
2
- Connect the motor to the terminal blocks (fig. 11):
terminal 3 = C common
terminal 4 = O open
terminal 5 = CL close
terminal 7 = GND ground
Connect the capacitor between terminals 4 and 5.
Pag. 7