background image

!

Fig. 12

Remove the power before to pick - up the protection 
plexiglass and operate on the terminal blocks.

5 - PROGRAMMING

6

5

4

3

2

1

ON

PR

LR

PV

LV

ON

1 2 3 4 5 6

OFF

Fig. 13

Operating time selection during the sequential and mixed 
mode

By positioning the dip-switches 1 to 5 on ON, during the operating 
modes sequential and mixed, it is possible to select the time-out of the 
motor.

Switch 1 = 

6 seconds

Switch 2 = 

12 seconds

Switch 3 = 

24 seconds

Switch 4 = 

48 seconds

Switch 5 = 

96 seconds

Multiple switches positioned on ON position causes the sum of the 
resulting time.

Command type setting

!

Local command

The transmitter strored on PR allow to operate in sequential, mixed 
or man present mode and by pushing only one key of the 
transmitter for all the movements (opening, stop and closing).

!

General command

It is necessary to have a 4 keys transmitter of the same series

The transmitters stored on PV allow to operate in sequential mode 
but need 3 keys, a key (B) to open a key (D) to close and a key (C) 
to stop.

During the movement (opening or closing) only the stop key (C) is 
enabled

In order to be sure of the complete drive of all 
the receivers, it is advisable to use the 
transmitter at the minimum distance (do not 
use over 20m)

!

 6 - TRANSMITTER CODES MEMORISATION

6

5

4

3

2

1

ON

PR

LR

PV

LV

ON

1 2 3 4 5 6

OFF

Fig. 14

Local command

Push and keep pushed the button PR of the reciver until the red led 
switches on; Within 4 seconds push the key of the transmitter to 
memorise.
The red led LR will switch off.

Repeat the same procedure for each transmitter key.

Pag. 8

 The operating mode of the radio-programmer is selected with the 
6-ways binary dip-switch ( Fig. 13.)

Operating mode

Dip-switch 1-5

Dip-switch 6

SEQUENTIAL 
( CYCLIC )

MIXED

MAN PRESENT

OFF

ON

According to 
selected time

According to 
selected time

OFF

OFF

Operating mode selection

WARNING: The use of the Man present mode causes a faster 
consumption of the transmitter battery.

24 V

8

10

12

14

9

11

13

15

L1

L2

3

 

-

 (fig. 12):

- if you want to use an antenna,( not supplied), connect the shield to 
the terminal 15 and the net to the terminal 14, otherwise if you use 
the antenna cable supplied, connect it to the terminal 14.
- if you want to connect an external command device (not supplied), 
connect the N.O. contact  to  the terminals 12 and 13.
-  a  safety  device  (  as  photocells,  with  n.c.  contact)  has  to  be 
connected between terminals 10 and 11;

NOTE1:If the terminals 10-11 are left unconnected, they have to be 
shorted. If the N.C. contact is not closed, the led L1 remains off. 
When this contact is activated, it causes the blockage of the motion 
both in opening and in closing. 

NOTE2:The  led  L2  switches  on  when  the  N.O.  contact    of  the 
external command is activated.

Connect the accessories as follows

The terminals 8-9 are an output of 24 Vac / 200 mA for external 
loads ( ex. photocells, etc.).

Содержание 024A Series

Страница 1: ...Radioprogrammer 750W R cepteur s quentiel 750W Funkmotorsteuerung 750W Manuale d installazione ed uso Italiano Pag 4 Use and installation Manual English Pag 7 Notices d installation et utilisation Fra...

Страница 2: ...nible l adresse internet suivante www erone com Declaration of Conformity Der hersteller CDVI Wireless Spa behauptet dass das funkger t entsprechend der vorschrift 2014 53 UE ist Die komplete beschrei...

Страница 3: ...i I O Terminal boards Bornes Anschl sse Led L2 Contatto NA esterno Led L2 NO external command Led L2 Contact NO exterieur Led L2 Sicherheitsvorrichtung 52 140 115 128 104 Tasto PR LR Push button PR LE...

Страница 4: ...one 230 Vac Potenza massima del motore 750 W Uscita ausiliaria 24 Vac 200 mA Capacit di memoria 100 Temperatura di funzionamento 20 70 C Grado di protezione IP44 Peso 380 gr Dimensioni 140 x 115 x 52...

Страница 5: ...cessitano di un solo pulsante del trasmettitore per aprire chiudere e fermare Il comando locale prioritario sul comando generale Comando generale E necessario disporre di un trasmettitore a 4 canali d...

Страница 6: ...i corrispondenza indica la quantit di trasmettitori memorizzati Verifica della posizione di un codice trasmettitore in memoria Premere sul pulsante del radiocomando che si desidera controllare e rilas...

Страница 7: ...maximum power 750 W Auxiliary output 24 Vac 200 mA Memory capacity 100 Operating temperature 20 70 C IP grade IP44 Weight 380 gr Overall dimensions 140 x 115 x 52 mm 2 TECHNICAL SPECIFICATIONS 4 INSTA...

Страница 8: ...14 Local command Push and keep pushed the button PR of the reciver until the red led switches on Within 4 seconds push the key of the transmitter to memorise The red led LR will switch off Repeat the...

Страница 9: ...The final number is equal to the total number of codes stored in the memory Check of the transmitter position inside the memory Push and release the transmitter button for which it is necessary the ch...

Страница 10: ...P44 Poids 380 gr Dimensions mm 140 x 115 x 52 3 FONCTIONNEMENTS S quentiel 1 impulsion provoque l ouverture 1 impulsion provoque la fermeture arr t sur temporisation ou impulsion Mixte 1 impulsion pro...

Страница 11: ...iller en mode s quentiel et n cessite trois touches d metteurs une touche canal B pour l ouverture une touche canal D pour la fermeture et un touche canal C pour l arr t En cours de travail ouverture...

Страница 12: ...pas de contr ler si un code a t m moris plus d une fois En cons quence il faut consid rer que si un metteur est enregistr deux fois ou plus il est n cessaire de le remplacer dans toutes les positions...

Страница 13: ...5 x 52 mm Daten SEL39R30 P7 Empf ngertyp Frequenz 433 92 MHz Frequenz des lokalen Oszillators 6 6128 MHz Modulation AM ASK Eingangsimpadanz 50 Ohm Zwischenfrequenz 10 7 MHz Empfindlichkeit f r erfolgr...

Страница 14: ...lter 2 ON 12 Sek Dip Schalter 3 ON 24 Sek Dip Schalter 4 ON 48 Sek Dip Schalter 5 ON 96 Sek Befehlsauswahl lokaler Befehl Die Sendertasten werden mit der Taste PR eingelernt f r die Funktionen sequent...

Страница 15: ...er Bin rsequenz berschreiben eines eingelernten Handsenders nur Modell 2641 R433P7 Ein verlorener oder defekter Handsender kann direkt durch berschreiben seiner Speicherposition gel scht und durch ein...

Страница 16: ...vom inneren angezeigten Herstellungsdatum W hrend solcher Periode wenn das Ger t nicht korrekt wegen eines defekten Bauelements arbeitet wird es beseitigt oder nach Hersteller Entscheidung ersetzt Die...

Отзывы: