CE/Safety

All electronic equipment can emit or be sensitive to induced electromagnetic noise, which can
be conducted by the connected wires or transmitted as electromagnetic fields.
Electromagnetic noise can cause malfunction or damage to the equipment.
The BED-108/2 are tested to, and fulfils, the following EMC standards:

EN 50081-1 (Emission)
EN 50130-4 (Immunity)

These standards covers equipment installed in an industrial environment.

The BED-108/2 fulfil the following safety standard:

IEC 60950

BED-108/2 Layout

The BED-108/2 has been designed for easy installation and set-up. The below figure shows
the layout of the Simplex RS485 Distribution Unit.

PWR

X1

X3

MAINS IN

X2

N L

MAINS

SELECT

F5

CC NC NO
Power Fail

Detect

ERNA

IN

-     +

- +

1

Ih 140

265VAC

DANGER

ACHTUNG

230

11

5

S1

Ih 1100

F6

XA1

XB1

- +

ERNA OUT

- +

- +

2

3

4

- +

5

- +

6

- +

7

- +

8

+10V

ON

0498-00053 V.0.1

XG1

XC1

XD1

XE1

XF1

H1

H2

TP1

TP2

XH1

DATA

TP3

ERNITEC

5

6

1 2

4

3

BED-108/2 Layout

8x RS485 outputs

6

RS485 input

5

Mains failure connection

4

Mains selection switch 115/230VAC

3

Mains terminal block

2

Safety Earth connection

1

BED-108/2

No.

Description

Installation Instructions BED-108/2

Page 4

3020-00041

 

Содержание BED-108/2

Страница 1: ...Installation Instructions BED 108 2 Simplex RS485 Distribution Amplifier 3020 00041...

Страница 2: ...box should be mounted on a plane surface to avoid twisting of the box resulting in possible leakage PWR X1 X3 MAINS IN X2 N L MAINS SELECT F5 CC NC NO Power Fail Detect ERNA IN 1 Ih 140 265VAC DANGER...

Страница 3: ...ed in order to avoid malfunction or damage to the BED 108 2 or the connected equipment All cables to and from the BED 108 2 are fed through the cable glands Choose an appropriate size gland for the ac...

Страница 4: ...ty standard IEC 60950 BED 108 2 Layout The BED 108 2 has been designed for easy installation and set up The below figure shows the layout of the Simplex RS485 Distribution Unit PWR X1 X3 MAINS IN X2 N...

Страница 5: ...Phase Neutral to Neutral and Earth to Earth Otherwise malfunction or even damage to the BED 108 2 will occur For specification of mains refer to Specifications at the end of these instructions RS485 E...

Страница 6: ...C 253 230 207 Mains input 230VAC 115 230VAC selectable VAC 126 115 104 Mains input 115VAC General using 0 6 mm solid copper twisted pair standard telephone cable 25 C km 5 Transmission distance Potent...

Страница 7: ...X 01903 77 27 07 E MAIL sally ernitec uk co uk GERMAN OFFICE ERNITEC GmbH STORMARNRING 28 22145 STAPELFELD GERMANY TELEPHONE 040 6756 25 0 TELEFAX 040 67 56 25 25 E MAIL ernitec aol com FRENCH OFFICE...

Отзывы: