Eriez HMDA Скачать руководство пользователя страница 7

Heavy Media Permanent Magnetic Wet Drum Separator

7

TANK STYLES

Style I ‑ Concurrent

This design is most effective for producing an 
extremely clean magnetic concentrate from relatively 
coarse materials and is widely used in heavy media 
recovery systems.

Feed is introduced at one end of the separator and 
flows in the direction of the drum rotation. Magnetic 
material is immediately picked up by the powerful 
magnetic element. As the material is transported by 
the revolving drum surface, the special magnetic 
element agitates the material to free entrapped 
non-magnetic particles. Non-magnetic material 
is discharged at the bottom through the tailings 
discharge opening. The magnetic particles are held 
to the drum surface and pass through an opening 
between the drum shell and the “squeeze-pan” where 
excess water is forced out. The magnetic material is 
then discharged on the discharge lip at the opposite 
side of the tank from the feed.

The relatively long travel of magnetic material through 
the water while being agitated by the special magnet 
design gives a good washing action and produces a 
clean magnetic concentrate.

It is very important in this type of separator that the 
proper water level be maintained. Overflow volume 
should be from 40% to 50% of total tailings flow. Feed 
to the separator must remain constant to insure proper 
water level. Either lowering of water level or allowing 
too much underflow will result in excessive losses of 
magnetic material or an insufficiently  
cleaned concentrate.

Operation

FIGURE 5

Style Ii ‑ Counter‑Rotation

This separator is used where occasional surges in 
feed must be handled, where magnetic material  
losses are to be held to a minimum while an extremely 
clean concentrate is not required, and when high 
solids loading is encountered. Feed is introduced to 
the drum which is rotating in a direction opposite to 
that of the pulp flow. Magnetic material is picked up 
by the drum and immediately discharged. Since the 
tailings must flow under the magnetic arc of the drum 
surface before discharging, losses are held  
to a minimum.

It is important in this type of separator (a) for the solids 
to be fine; (b) to provide oversize protection to screen 
out solids larger than 1/4" (6 mm), and (c) that proper 
water level be maintained with overflow volume 40% 
to 50% of total tailings to prevent excessive losses.

Style Iii ‑ Self‑Leveling Counter‑Rotation

The Eriez Self-Leveling Wet Drum Magnetic 
Separator represents the newest available technology. 
This separator combines the best engineering 
and operational features and provides excellent 
performance with ease of operation, inspection,  
and maintenance.

The Eriez Self-Leveling tank has no discharge  
spigots to adjust. The tank level is controlled by 
removable weir bars on the discharge side of the tank. 
This arrangement allows the operator to maintain a 
constant tank level at any flowrate. The high capacity 
tank design accommodates surges and fluctuations  
in the feed rate. After startup no adjustment or 
monitoring are required.

FIGURE 6

Содержание HMDA

Страница 1: ...n Operation and Maintenance Instructions ERIEZ MAGNETICS HEADQUARTERS 2200 ASBURY ROAD ERIE PA 16506 1402 U S A WORLD AUTHORITY IN ADVANCED TECHNOLOGY FOR MAGNETIC VIBRATORY and INSPECTION APPLICATION...

Страница 2: ...equipment If you use a heart pacemaker or similar device you must never approach the equipment because your device may malfunction in the magnetic field with consequences up to and including death To...

Страница 3: ...ator 3 Table of Contents ERIEZ MODEL HMDA WET DRUM MAGNETIC SEPARATOR GENERAL DESCRIPTION 4 INSTALLATION 5 General 5 Adjustments 5 OPERATION 6 Adjustments 6 Style I Concurrent 7 Style II Counter Rotat...

Страница 4: ...ed by a rugged steel frame CAUTION DO NOT apply slings to the drum shell to lift the drum separator Lift the separator by lugs provided or attach a sling to the frame If the drum is to be removed slin...

Страница 5: ...position may change during shipment due to road transport vibration etc If this occurs the magnetic element must be re positioned Note that the magnet position is indicated by a scribed and painted s...

Страница 6: ...owever slight adjustment up or down can be made from the normal position to obtain optimum results In which the magnitite is in the horizontal plain stick outward at the discharge lip Operation FIGURE...

Страница 7: ...ow will result in excessive losses of magnetic material or an insufficiently cleaned concentrate Operation FIGURE 5 Style Ii Counter Rotation This separator is used where occasional surges in feed mus...

Страница 8: ...schedule for maintenance be conducted as follows DRUM BEARINGS All flange cartridge bearings require lubrication Wipe all fittings to remove dirt and use a clean grease gun which has been filled with...