External Timing Cables
A-4
SmartEdge 1200 Router Hardware Guide
To bring a signal from external equipment into the SmartEdge router:
• For the DS-1 interface (BITS):
You must connect the DS-1 output of the external equipment to pins 2 and 6 of the DB-9 connector on
the rear panel of the SmartEdge chassis. The polarity of the signal does not matter. The SmartEdge
system accepts a standard BITS source transmitting a framed-all-ones pattern at the DS-1 rate of
1.544 Mbps.
• For the E1 interface (SSU):
You must connect the E1 output of the external equipment to pins 2 and 6 of the SSU DB-9 connector
on the rear panel of a SmartEdge chassis. The polarity of the signal does not matter. A SmartEdge
system accepts a standard synchronization source transmitting an HDB3-encoded, framed-all-ones
pattern at the E1 rate of 2.048 Mbps.
Table A-6 lists the pin assignments for either cable.
Note
An adapter, available as an option, provides wirewrap pins to allow you to attach a cable
without a connector.
Table A-6
External Timing Cable Pin Assignments
#
Signal Name
1
1. The direction, input or output, is with respect to the controller card: input describes data flowing
into the controller card; output describes data being transmitted by the controller card.
Color
Notes
1.
Shield
Bare Wire
Frame ground connection
2.
External equipment input (+)
White
Twisted pair with pin 6
3.
–
–
No connection
4.
External equipment output (+)
White
Twisted pair with pin 9
5.
Shield
Bare Wire
Frame ground connection
6.
External equipment input (–)
Blue
Twisted pair with pin 2
7.
–
–
No connection
8.
–
–
No connection
9.
External equipment output (–)
Orange
Twisted pair with pin 4