Unit Decription, CDU-G and CDU-F
TX Part Description
CDU-G consists of two identical TX chains.
The TX part contains a lowpass filter and a duplex filter. The lowpass
filter secures the required reverse isolation. It also reduces spuriouses
from the transmitter on the frequencies higher than the TX band. The
duplex filter (DPX) allows using a single antenna for both transmitting
and receiving.
There is an Measurement Coupler Unit (MCU) between the DPX and
antenna connector. The MCU samples forwarded and reflected signals
and distributes them to the Measurement Receiver (MR) for antenna
return loss monitoring.
RX Part Description
CDU-G consists of two identical RX chains.
The RX parts consist of a filter and a low noise amplifier (LNA). The
receiving filter is included in the duplex filter.
Distribution of RX signals is performed in the Configuration Switching
Unit (CXU).
Block Diagram
TXLP
DPX MCU
TXLP
DPX
MR
Filter unit 1
Filter unit 2
Tx 1
Rx 1
Rx 2
Tx 2
TX/RX 1
CDU Bus
DC in
TX/RX 2
MCU
P007449B
Figure 90
Block diagram of CDU-G
160 (485)
EN/LZT 720 0008
P2A
2001-11-28
© Ericsson Radio Systems AB
— All Rights Reserved —