Product Data RBS 2206
OVP for External Alarm
It is possible to connect 16 external alarms to the DF. Each alarm
connection is provided with over-voltage protection. (One OVP module
protects two alarm connections.)
OVP Module for PCM Lines
The distribution Frame (DF) provides overvoltage protection for PCM-
lines. In addition, a PCM-line can be provided with a blaun (balanced/
unbalanced transformer) to convert an unbalanced 75
line to a
balanced 120
line.
P008443A
OVP Board
By-pass Board,
Balun Board,
or Dummy Board
Figure 56
OVP module for PCM lines
Each module provides overvoltage protection for two PCM lines.
The overvoltage protectors (OVP) are mounted on an OVP board
inserted into a slot connector in the OVP module. An OVP board
contains gas discharge tubes and serial fuses for protection of two lines.
The other slot connector in the OVP module can be equipped with
several options:
•
A dummy board, when the transmission system is twisted pairs.
124 (485)
EN/LZT 720 0008
P2A
2001-11-28
© Ericsson Radio Systems AB
— All Rights Reserved —