BRU3 LOGIC AND RADIO SYSTEM
31 (34)
BRU3 MANUAL, Doc.no: 155 16-ANNA 805 08 Uen, Rev H, 2003-02-07
9.1
I/O CONNECTIONS
MOX connection:
Number of ports
3 DMA support
Port locations
FNB
Alternative 1 (One alternative at a time only)
----------------
Communication interface
RS232D
----------------
Communication baudrate
Max. 19.2 kbps
Alternative 2
----------------
Communication interface
RS422
----------------
Communication baudrate
Max. 64 kbps
Alternative 3
----------------
Communication interface
V.32
----------------
Communication baudrate
Max 9.6 kbps
Alternative 4
----------------
Communication interface
V.32bis
----------------
Communication baudrate
Max 14.4 kbps
Console/NODOP connection:
Number of ports
1
Port location
FNB
Communication interface
RS232D
Communication baudrate
9.6 kbps
External hardware alarm connections:
Number of alarm inputs
2
Port location
FNB
One of the external alarm loops is by default strapped for the open case alarm.
Antenna connections:
Number of connections
1 or 2 (Duplex or Bandpass filter),
Located on FNB
Connector type
TNC, female