MINI-LINK BAS
9-6
Technical Description
EN/LZB 111 0542 P2B
macSwdlFromActiveToRa
dioInProgress
Eq
Minor
A background downloads from the MAC FPROM
active part towards the passive area of Radio in
progress at RN side.
macModemSwDownload
Failure
Eq
Major
The download from the MAC FPROM active or
passive towards the passive area of Modem has
failed at RN side.
macRadioSwDownloadFa
ilure
Eq
Major
The download from the MAC FPROM active or
passive towards the passive area of Radio has
failed at RN side.
mcnWarning
Eq
Warning
The alarm is issued only after system restart in
order to verify that the MCN channel is properly
working.
modemControlChannel
Comm
Major
No communication with RAU processor. Alarm
detected both at AT and RN sides.
modemEberUp
Comm
Major
The Eber received by the modem has exceeded
the allowed limit. Alarm detected at RN side.
modemEberDown
Comm
Major
The Eber received by the modem has exceeded
the allowed limit. Alarm detected at AT side.
modemHwException
Eq
Major
Hardware internal fault
modemLoftTdm
Eq
Major
AT modem has lost the downstream frame
alignment
modemModInd
Eq
Minor
Unable to adjust modulation index
modemRauPow
Comm
Critical
RAU power supply failure
modemRxIFinUp
Comm
Major
Input level from RAU is too low. Alarm detected at
RN side.
modemRxIFDown
Comm
Major
Input level from RAU is too low. Alarm detected at
AT side.
msAis
Comm
Minor
It is sent when alarm indication signal is received
for more than 2.5 sec on a multiplexer section.
msRdi
Comm
Minor
It is sent when remote defect indication is received
for more than 2.5 sec on a multiplexer section.
pathAis
Comm
Minor
It is sent when alarm indication signal is received
for more than 2.5 sec on a path.
pathRdi
Comm
Minor
It is sent when remote defect indication is received
for more than 2.5 sec on a path.
powerFailure
Eq
Critical
It is sent when a power failure has been detected in
the subrack. An alarm ceasing report, alarm
severity cleared, will be sent when an indication
that the power is back on has been detected.
powerLoss
Eq
Minor
It is sent when a power loss occurs at a board.
radioHighTemperature
Eq
Minor
Outdoor temperature above limit
radioRfOut
Comm
Major
RF output level to antenna to low.
radioRxFreq
Comm
Critical
Received frequency incorrect, Rx RF PLL unlocked
Содержание MINI-LINK BAS
Страница 1: ...MINI LINK BAS Technical Description...
Страница 12: ...MINI LINK BAS 10 Technical Description EN LZB 111 0542 P2B...
Страница 13: ...1 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description Introduction...
Страница 22: ...MINI LINK BAS 1 10 Technical Description EN LZB 111 0542 P2B...
Страница 23: ...2 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description System Description...
Страница 37: ...3 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description Network Architecture...
Страница 49: ...4 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description End User Services...
Страница 56: ...MINI LINK BAS 4 8 Technical Description EN LZB 111 0542 P2B...
Страница 57: ...5 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description Physical and MAC Layers...
Страница 84: ...MINI LINK BAS 5 28 Technical Description EN LZB 111 0542 P2B...
Страница 85: ...6 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description Management and Control...
Страница 118: ...MINI LINK BAS 6 34 Technical Description EN LZB 111 0542 P2B...
Страница 119: ...7 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description ATM Transport and Multiplexing...
Страница 127: ...8 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description Equipment Practice and Power...
Страница 147: ...9 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description O M Facilities...
Страница 169: ...11 1 MINI LINK BAS EN LZB 111 0542 P2B Technical Description Index...
Страница 174: ...MINI LINK BAS 11 6 Technical Description EN LZB 111 0542 P2B...