1/1531-CRA 119 0513/30 Uen A 2007-11-15
2
Configuration of OMS 870
2
2.1
Initial configuration
2.1.1
Commissioning of IP address via VT100 Interface
2.1.1.1
Brief Description
A local terminal with VT100 emulation is required during the first
commissioning of the network element in order to set up the necessary
communications parameters enabling access to the element via AXX
9820 CRAFT over the Management Port. After the first commissioning, a
VT100 interface can be used for modifying the communications
parameters and perform some status checks of the network element.
The VT100 interface is password protected.
Commissioning of IP address via a VT100 Interface
CLI is a line-oriented ASCII-based management interface embedded in
the network element.The CLI is accessed via the VT100-port. The serial
connection communications parameters are fixed:
•
19200 bit/s,
•
no parity,
•
8 bits,
•
1 stop bit,
•
and no hardware flow control.
VT100 terminal codes are used. Default Telnet password is telnet.
The VT100-port (Console port) for the network element is provided using
a RJ-45 connector. The cable for connecting the VT100-port to the serial-
port on the PC can be provided. The specification of this cable is the
following:
Figure 15 VT100-CABLE (Console cable)