Marconi OMS 870 R3.0 Quick Reference Guide
Flashing green LED on Ethernet related modules during shutdown.
Flashing green LED after inserting a service module in Base Unit
indicates that the module is receiving a firmware to align the status
for Network release level stored on the system controller. This will
only be triggered when the Update policy is enabled for the service
module being inserted. An event will be reported in this case.
EXTINGUISHED
Indicates that the module is Out-of-Service. Module can be
removed.
A module is taken Out-of-Service by an operator shutdown-
command or by activation of the shutdown button, as described in
“Hot insertion and removal” on page 1 -17
N O T E !
Flashing green LED on Ethernet related modules during
shutdown.
N O T E !
Flashing green LED after inserting a service module in Base
Unit indicate that the module is receiving a firmware to align
the status for Network release level stored on the system
controller. This will only be triggered when the Update policy
is enabled for the service module being inserted. An event
will be reported in this case.
1.7.3
Hot insertion and removal
The OMS 870 service modules supports hot insertion and removal.
Each module contain a switch that is activated when the module
shall be removed, see Figure 6
A special tool, the Card Extraction Tool must be used to activate the
switch, see Figure 7