LBI-38962
30
CONNECTING TO AN AC SOURCE
The EDG comes with two different AC line cords: one for use in the United States and the other for international
use. One end of the international line cord does not have a plug on it so that you can add the connector needed for
your country. Use the following instructions to connect the EDG to an AC source.
1)
Open the back door of the EDG cabinet and locate the J1 connector on the back of the power supply
subassembly.
2)
Insert the twist lock connector on the line cord into the J1 connector and turn it clockwise to lock it in
place.
3)
Plug the other end of the line cord into the wall outlet.
UPDATING THE SYSTEM MANAGER DATABASE
For each TSI Master, enter a LID in the System Manager Database in the range from 64 to 16,382. Since the
System Manager doesn't currently support an EDG TSI as a valid type, add them as radio types but assign labels
such as "EDG TSI 1" for reference.
CUSTOMIZING THE EDG CONFIGURATION
1)
Copy the files on the Configuration diskette to a working diskette using a MS-DOS PC.
2)
Edit the SYSTEM.TXT configuration file to customize it. The TSI EDACS IDs entered into the System
Manager must be entered in this file using the TSI_EDACS_ID command. The other items changed in
most installations are:
•
IP Addresses ([IP] CAP_EXT_ADDRESS, [IP] INT_NETWORK_ID, and [IMC]
EDACS_IP_NETWORK_ID commands)
•
Host entries in the [IP_MAP_ID_TABLE] section, if using IP hosts
•
HDI host entries ([BOARD] HDI_PORT_HOSTS command), if using RDI hosts
•
Transport Layer Protocol ([SYSTEM] TRANSPORT_LAYER_PROTOCOL command), if any
non-network layer RDTs are being used.
•
Identification of GIDs and LIDs assigned to network layer RDTs, if used
([NETWORK_LAYER_RDT_TABLE] heading)
In addition, security can be increased by setting the maximum number of Telnet and FTP sessions to 0.
This disables Telnet and FTP sessions into the EDG.
3)
Verify your configuration when done by entering "syscheck" at the DOS prompt, while on the working
diskette.
4)
Insert your configuration working diskette in the EDG floppy drive prior to turning on or rebooting the
EDG.
Refer to the EDG Configuration Reference Manual for more information.