FOR BEST PERFORMANCE
1.
Charge battery to full capacity, 14 hours at the
standard C/10 rate (capacity X .10). For "rapid"
chargers, allow additional time (2-3 hours) for "top-
ping off" the charge after it switches from "fast" to
"slow".
2.
Use the battery soon and use as much of the battery
capacity as possible or practical. A battery that is
charged and discharged completely will maintain
the longest running time capacity. Also, several
charge/discharge cycles are recommended to bring
a new battery up to its rated capacity.
3.
Store and charge the batteries at room temperature
65°F to 75°F. Batteries that have been stored for
over a month should be recharged before putting
into service due to chemical self-discharge which
occurs at a rate of approximately 1% per day. Do not
charge cold batteries (40°F or below).
4.
Reduced capacity or "memory effect" may result
from repeated identical shallow discharge/full re-
charge cycles. If such a condition is suspected, run
the battery until the instrumentation loses all power,
then fully recharge and discharge again. Repeat this
cycle 3-4 times.