LBI-39190
39
Network Connections
Problem
Corrective Actions
IP host can not
reach Data
Advantage
1. Verify that the Yellow Ethernet LED is lit on the 714 module. If it isn’t check the
fuse on the CAP Board.
2. Verify that the Data Advantage is physically connected to the LAN network.
3. Verify that the host and the Data Advantage CAP external network interface are on
the same subnet.
4. If the host and the Data Advantage are not on the same subnet, verify that the host
has a route entry specifying a gateway to the Data Advantage.
IP host can reach
the CAP board , but
not the WNI
board(s).
1. Verify that the host has a route entry which specifies the CAP external IP address as
the next gateway to the Internal Network of the Data Advantage.
2. Verify that the Backplane Network Interface of the Data Advantage is enabled.
IP host can reach
both the CAP and
the WNI board, but
not the radios on
the EDACS
network.
1. Verify that the host has a route entry which specifies the CAP external IP address as
the next gateway to the EDACS network.
2. Verify that the mapping between the LID and the IP address of the destination
radio is correct.
RDT can not reach
the IP host.
1. Verify that the IP host and the Data Advantage are on the same subnet.
2. If the IP host and the Data Advantage are not on the same subnet, verify that the Data
Advantage has a route entry which specifies a next gateway to the IP host. If this is
not the case, add the route entry to the Data Advantage (use “route add” command or
add an entry to the External Routing Table in the SYSTEM.TXT).
3. If the RDT does not have a Network Layer, verify that there is a mapping
between a Data Advantage port and the IP address of the host in the SYSTEM.TXT.