8 (28)
BRU1 MANUAL
BRU1 MANUAL, Doc.no: b1sitreq Uen Rev PA5, 2004-02-19
3.5.1
General
The space specified in this document is a minimum to allow an adequate airflow
around the equipment. The customer decides if any additional working space is
needed around the BRU1. The BRU1 can be mounted in two directions, either
with the antenna facing up, or with the antenna facing down. The building
material in the walls and ceiling may interfere with the antenna and the position
of the BRU1 must therefore be made carefully.
3.5.2
Above the BRU1
Minimum: 300 mm
A minimum of 300 mm free space is necessary above the case.
3.5.3
Below the BRU1
Minimum: 300 mm
To be able to run the cables safely, 300 mm of free space is necessary below the
case. The distance also allow an adequate airflow around the equipment.