8.4
Connecting the RS422B Line
Locate the RS422 connector (see
) and connect the cable.
8.4.1
RS422B Port Pinout and Characteristics
Figure 12 RS422 connector.
Communication:
Synchronous, serial
Speed:
Max. 64.000 bps
Electrical:
V.11 (EIA-422-A)
Logical signals:
V.24, RS-530 standard
BRU1 end connector:
D-SUB 25-pole, female
Max. dist. to DCE:
A few kilometres, depending on transmission speed
and type of cable.
ERROR
RS232
RS422
10BaseT
SYSTEM OK
CONSOLE
RS422
RS232
POWER
FUSE
3 A F
+24 VDC
Rx
L
8
9/1424-LZE 401 204 Uen Re