MODIFICATION PROCEDURE
1.
Unplug unit from power source.
2.
Cut BRN lead near S1 and cover the short end of wire
to prevent accidental contact.
3.
Strip 1/2" of insulation from long portion of BRN
lead (just cut).
4.
Remove wirenut holding BLK/WHT to BRN/WHT
leads.
5.
Fasten BRN and BLK/WHT leads together using
wirenut (see Diagram for 240 Volt operation).
6.
Cover/insulate exposed BRN/WHT lead to prevent
accidental contact.
7.
Move BLACK wire from J7 to J8.
Power supply can now be used with a 240 Volt, 50/60 Hz,
single phase source.
WIRED FOR 120 VOLT
OPERATION
WIRED FOR 240 VOLT
OPERATION
ADAPTER CABLE
Where the 19A704647P11 unit is used in a desktop station
application, an adapter cable 19B803437P1 must be used
between the power supply DC output jack and the station
power cable.