© 2001 – Ericsson Amplifier Technologies Inc.
5
2.5 Environmental Limitations
The MCPA is designed to operate in an environment as noted in Table 1 of this
manual. The MCPA must be installed in an area where an adequate and unrestricted
supply of air is available for cooling. Adequate clearance must be provided to prevent
obstruction of airflow. Confirm that proper dc power is available for the equipment.
2.6 Installation
The amplifier is produced in a Blind Mate configuration as shown in Figure 2. The
Blind Mate configuration is designed for mounting in an Ericsson Amplifier
Technologies subrack, and features a single connector on the rear panel for all RF, DC
and I/O interface connections. The following paragraphs provide installation details.
2.6.1 Recommended Tools
The following tools are recommended to assist in the installation of the amplifier.
•
#1 and #2 Phillips screwdrivers
•
Slotted screwdrivers, 1/8” and 1/4”
•
A 5/16” or 3.5mm open-end wrench
•
A multi-meter with probes
2.6.2 Blind Mate Configuration Mounting
a. Install an amplifier module into each of the mating slots of the subrack, beginning
from the left. Use firm, but not excessive force when installing the amplifiers to
ensure a good connection is made.
b. Hand tighten the retaining screws on the front panels of the amplifier modules. Do
not over tighten.
c. Ensure that an unrestricted supply of air is available at the front and rear of the
enclosure for cooling.
Содержание 1/KRB 101 1108
Страница 11: ... 2001 Ericsson Amplifier Technologies Inc ...
Страница 29: ... 2001 Ericsson Amplifier Technologies Inc ...