PRELIMINARY
Radio Description
For Radio 2217 and Radio 2218 allow for a minimum of 40 mm free space
between radios installed side by side on the rail when ambient temperature is
expected to be above +45
C.
3.3.3.2
Radio Installation on Indoor Wall
The installation requirements if installing the radio on an indoor wall are shown
in Figure 10.
Unit of measurement: mm
>400
Ge9000A
Front View
>300
>300
>7
>7
>1000
Top View
>7
>7
Figure 10
Radio Indoor Wall Installation Requirements
To ensure adequate airflow between the units, allow a minimum of 400 mm free
space between radios vertically installed on a horizontal rail on a wall. The
minimum distance from the bottom of the radio to the floor is 300 mm.
Allow a minimum of 7 mm free space (created by the distance blocks) between
radios installed side by side on the rail.
For Radio 2217 and Radio 2218 allow for a minimum of 40 mm free space
between radios installed side by side on the rail when ambient temperature is
expected to be above +45
C.
20
181/1551-LZA 701 6001-1-V1 Uen PC3
|