PRELIMINARY
Radio Description
3.5.2
Heat Dissipation
The radio is convection cooled and designed for outdoor installation. Table 7
shows the radio output power and maximum heat dissipation. Indoor installation
in a room without adequate ventilation and cooling must be avoided.
Table 7
Radio Heat Dissipation
Unit
Output Power (W)
Maximum Heat
Dissipation (kW)
Radio 2217 B1
2 x 40
0.22
Radio 2217 B3
2 x 40
0.22
Radio 2217 B8
2 x 40
0.22
Radio 2217 B20
2 x 40
0.25
Radio 2217 B28A
2 x 40
0.25
Radio 2217 B5
2 x 40
0.32
Radio 2218 B39A
2 x 40
0.27
Radio 0208 B1
N/A
0.036
3.5.3
Vibration
This section describes the radio tolerance to vibrations. The radio operates
reliably during seismic activity as specified by test method IEC 60068-2-57 Ff.
Maximum level of Required Response
Spectrum (RRS)
50 m/s
2
within 2–5 Hz for DR=2%
Frequency range
1–35 Hz
Time history signal
Verteq II
The radio operates reliably during random vibration as specified by test method
IEC 60068-2-64 Fh
Random vibration, normal operation
0.3 m
2
/s
3
3.5.4
Materials
This section contains information about materials.
All Ericsson products fulfill the legal and market requirements regarding the
following:
•
Material declaration
22
181/1551-LZA 701 6001-1-V1 Uen PC3
|
2016-01-13
Содержание 0208
Страница 1: ...Exhibit 8 Manual Confidential...
Страница 7: ...P R E L I M I N A R Y Radio Description 2 181 1551 LZA 701 6001 1 V1 Uen PC3 2016 01 13...
Страница 11: ...P R E L I M I N A R Y Radio Description 6 181 1551 LZA 701 6001 1 V1 Uen PC3 2016 01 13...
Страница 31: ...P R E L I M I N A R Y Radio Description 26 181 1551 LZA 701 6001 1 V1 Uen PC3 2016 01 13...
Страница 49: ...P R E L I M I N A R Y Radio Description 44 181 1551 LZA 701 6001 1 V1 Uen PC3 2016 01 13...