background image

4 of 8

300-5577-00 rev. J • 10/16

3/4" Button Hd PB Screw 

325-5575-00

A

B

M6-10 Button-head Screw

325-5503-00

C

D

M6x14 Flat Hd Screw

325-5435-00

3/4" Button Hd PB Screw 

325-5575-00

E

S T E P   1   -   AT TAC H   G U S S E T S  TO  TO P

Lay the worksurface upside down on a cushioned, non-marring surface.  

Locate the front edge of the table.  On Plus tables, the front of the table 
has a sloping waterfall edge.  On the Basic tables, the back edge of the 
table has the seam where the edgebanding meets.

Align the Leg Gussets with the holes on the top so the upright fl ange faces 

the outside of the table and the tapering end points to the front of the 
table.

Attach each gusset to the worksurface with six 3/4" Button Hd PB Screws  

(325-5575-00) using the Anthro driver.

S T E P   2   -   I N S TA L L   L E G S

 

Align one Leg with one Leg Gusset so the cord feeds out of the 
Leg toward the center of the table.  The Leg will rest on top of the 
Gusset's button-head screws, so it may feel a little wobbly. [A]

 

Slide a Leg Housing over the Leg and down until it covers the Leg 
Motor and the six screw holes on the housing line up with the six    
pre-drilled holes on the shelf.  [B]

 

Move to the front of the table and attach the front of the Housing 
to the Leg with two M6-10MM Button Hd Screws (325-5503-00) 
using the Anthro driver.  Tilt the leg slightly to align the holes.  [C]

 

Loosely attach the Housing to the shelf with six 3/4" Button Hd PB 
Screws (325-5575-00). [D]

 

Attach the side of the Leg to the Leg Gusset with two M6-14 Flat-
head Screws (325-5435-00). [E]

 

Repeat for the other Leg and Housing.

Содержание Elevate II

Страница 1: ... 10 16 Product Part Elevate II 48w 29d MVBD48SS xx Elevate II 60w 29d MVBD60SS xx Built with Anthro DNA For the latest User Installation Guide please visit www ergotron com ASSEMBLY INSTRUCTIONS Elevate II Single Surface Table ...

Страница 2: ...ent il est important de respecter certaines précautions de base notamment celles décrites ci dessous Lire intégralement les consignes avant d utiliser ce mobilier DANGER Pour limiter le risque de choc électrique toujours débrancher le mobilier avant de nettoyer AVERTISSEMENT Pour limiter les risques de brûlure d incendie de choc électrique ou de blessure aux personnes 1 Débrancher avant d installe...

Страница 3: ...ew 31 325 5575 00 14 M6 10 Button head Screw 8 325 5503 00 15 M6x14 Flat head Screw 4 325 5435 00 16 3 4 Phillips SMS Zinc Screw 4 325 5370 00 17 1 2 Button hd Screw 3 325 5193 00 18 10 24 Nylock Nut 3 325 5186 00 19 M6 20 Cap Screw 8 325 5272 00 20 Control Box Cable not shown 2 400 5182 00 21 1 75 Phillips SMS Pan hd Screw 2 325 5772 00 not shown WELCOME Thank you for purchasing Anthro s Elevate ...

Страница 4: ...face with six 3 4 Button Hd PB Screws 325 5575 00 using the Anthro driver STEP 2 INSTALL LEGS Align one Leg with one Leg Gusset so the cord feeds out of the Leg toward the center of the table The Leg will rest on top of the Gusset s button head screws so it may feel a little wobbly A Slide a Leg Housing over the Leg and down until it covers the Leg Motor and the six screw holes on the housing line...

Страница 5: ...he keypad and its slider housing with the four pre drilled holes at the front of the keyboard surface so the buttons are face down at the front edge of the keyboard surface and the flat side of the housing is against the shelf The keypad can also be installed directly to the worksurface without the slider housing either so it extends in front of the table or so it s set back a bit Using four Phill...

Страница 6: ...l Box Feed extra cable length through an opening in the support pan so it s organized in the Cable Tray Plug the Power Cord into the Control Box Use the provided cable clips to route and organize cords Install one cable clip next to the Leg Gusset for the Keypad Cord Install the other clip next to the Cross Pan for the Control Box Cables Step 6 INSTALL FEET AND HOME THE LEGS Align one foot with ea...

Страница 7: ...table to its lowest position release the DOWN button then press and hold the DOWN button for 5 seconds The table will bump a few times then rest Raise the table to its highest position Watch all the cords and cables as the table moves to verify that cords aren t wrapped around anything and that nothing interferes with the movement of the table Every time you add equipment onto the table route cord...

Страница 8: ...n rest Table won t move at all no up no down Has the table exceeded its duty cycle moving more than 6 minutes per hour or 2 minutes continuously If so rest the table for 20 minutes and try again Inspect the leg cables control box cable and power cable to be sure they are connected properly and not damaged Contact Anthro for replacements Test the cables Unplug the Leg Cable that is plugged into Por...

Отзывы: