background image

11

 

 

     Comissioning / Operation 

 

 

3.4

 

Teach-in process

 

This teach-in process is normally 

carried out by the manufacturer and 

you can skip this step.

 

If the status LED 

and the keypad 

illumination are flashing, the remote 

control has not yet been taught in on 

the dual drive.

 

In the following it is assumed that this is 

the case. It will be described how the 

teach-in process has to be carried 

out.

 

 

Briefly press any button on the 

remote control

 

 

The status LED 

and the keypad 

illumination flash alternately.

 

 

Press button 

L

 on the double 

drive for approx. 1 s.

 

 

The back adjustment motor 

moves briefly up/down.

 

 

The status LED 

goes off, the 

keypad illumination lights up 

constantly. The teach-in process has 

been completed successfully.

 

 

If the status LED 

and the keypad 

illumination do not flash, but a 

connection between double drive and 

remote control is still not established 

(bed cannot be adjusted), the double 

drive and remote control must be 

reset to the factory settings and re- 

taught. Resetting to factory settings is 

explained on page 13 of this manual.

 

 

 

3.5

 

Initial position

 

Before you adjust the bed for the first 

time, you should move the adjustment 

drives to their starting position.

 

 

Press button 

and keep it pressed.

 

 

The adjustment drives move to their 

initial position and switch off then.

 

Содержание VFF/CDL-BF-11

Страница 1: ...Radio remote control VFF CDL BF 11 with Bluetooth Technology Operating Instructions ...

Страница 2: ...2 Foreword Foreword Revision history Version Date 1 0 11 03 2020 Change First edition In your own interest Read these operation instructions and keep them in a safe place Observe the safety instructions ...

Страница 3: ...uctions 6 2 4 Information about radio operation 7 2 5 Handling Batteries 8 2 6 Electronic medical equipment 8 3 Commissioning Operation 9 13 3 1 The remote control 9 3 2 The control unit 10 3 3 Inserting the batteries 10 3 4 Teach in process 11 3 5 Initial position 11 3 6 Bed adjustment 12 3 7 Memory positions 12 3 8 Torch function 13 3 9 Reset to factory settings 13 4 Malfunctions troubleshooting...

Страница 4: ......

Страница 5: ...repairs and failures These operating instructions were compiled with great care No liability will be assumed for the accuracy and completeness of the data images or drawings unless prescribed by law Subject to technical amendments that serve continuous product improve ment without prior announcement 2 Safety instructions The radio remote control can be used by children aged 8 and upwards and by pe...

Страница 6: ...be used with a medical product or installed in a medical product in an environment in which there are inflammable or explosive gases or vapours e g anaesthetics in damp environments outdoors in applications that are washed in mechanical washing systems for lifting and lowering of loads in craftsman or industrial areas or in the household 2 3 Specific safety instructions Caution The following safet...

Страница 7: ...herwise the warranty will become void Operation The remote control only functions correctly if it is commissioned and used properly To avoid injury never allow children or other vulnerable persons to use the remote control unsupervised Radio signals can pass through walls and ceilings Only use the remote control in the room in which the adjustablebed islocated 2 4 Information about radio operation...

Страница 8: ...es and goggles should be worn when replacing leaking batteries Avoid touching leaking batteries with your bare hands as far as possible Should you come into contact with leaked battery components wash your hands thoroughly Remove any electrolyte residues by damp wiping Wash any clothes that come into contact with the electrolyte 2 6 Electronic medical devices This product is designed and manufactu...

Страница 9: ...9 Inbetriebnahme 3 Comissioning Operation 3 1 The remote control ...

Страница 10: ...o the battery compart ment as shown in the picture Ensure that the batteries are inserted in the right direction Once the batteries have been inser ted close the battery compartment lid again and the radio remote control is operational 1 Optional not to be operated with this remote control Comissioning ...

Страница 11: ... 1 s The back adjustment motor moves briefly up down The status LED s goes off the keypad illumination lights up constantly Theteach inprocesshas been completed successfully If the status LED s and the keypad illumination do not flash but a connection between double drive and remote control is still not established bed cannot be adjusted the double drive and remote control must be reset to the fac...

Страница 12: ...urrent position is assigned to the corresponding memory button and saved Recalling memory positions Caution Before using the memory buttons Check that neither you nor anyone else or any pets are at risk from the moving parts of the adjustment mechanics Stored positions can be recalled with the memory buttons Proceed as follows Press one of the buttons 7or 8 and keep it pressed The adjustment drive...

Страница 13: ...and hold the buttons 1 3 and 5 or 2 4 and 6 The status LED starts flashing When the status LED is steady release the buttons The status LED goes off the remote control is reset Resetting the double drive Pressbutton L on the double drive for approx 10 s The drive for the leg adjustment moves briefly to confirm a reset to the factory settings Remove the plug from the mains socket and wait for at le...

Страница 14: ...ess again see page 11 Reset the control unit to the default settings see page 13 and then carry out the teach in process again see page 11 5 Technical data Operating voltage 3VDC via batteries Power consumption Idle typ 1µA Operational 2mA Transmission freq 2 4GHz ISM Band Transmission range 10 50m Housing material ABS Protection grade P20 Battery type 2 pcs 1 5V AAA LR03 Weight incl batteries and...

Страница 15: ... equipment helps conserve natural resources and guarantees recycling which protects human health and preserves the environment Please contact your local council or waste disposal authority to find out where the collection points are for your old equipment Disposal of the radio remote control in Germany is subject to the Electrical Equipment Act internationally to the EU Directive 2011 65 EU RoHS o...

Страница 16: ...erved It is strictly forbidden to duplicate this document in any form without the prior consent of the company LS Bedding nv LS Bedding nv is not liable for any errors in this document or for any ensuing damages connected to the delivery performance or use of this material ...

Отзывы: