Ergonomic products Safe-T-Shield VacTrac Скачать руководство пользователя страница 4

950-109 rev A

ergonomic products • 198 Airport Rd • Fall River, MA 02720 • 866-374-6487

PAGE 4

Safe-T-Shield™ VacTrac 

Model T2B1

2 - CAUTIONS AND SAFETY INFORMATION

SYMBOLS USED IN THIS GUIDE

If the instructions are not followed properly, operation 

may lead to hazards for the product, user or patient.

Useful information that will increase performance or ease 

of use.

                        

BEFORE OPERATING YOUR SAFE-T-SHIELD FOR THE FIRST TIME:

1.  Thoroughly clean and disinfect the unit using standard maintenance 

protocols. See page 19.

Содержание Safe-T-Shield VacTrac

Страница 1: ...Product ID T2B1 Manual 950 109 rev A Safe T Shield VacTrac INSTALLATION MANUAL...

Страница 2: ...rgonomic Products Safe T Shield VacTrac Years of research by dentists engineers and designers have made this a uniquely effective product in the industry We stand behind our equipment and genuinely be...

Страница 3: ...ble PPE regime The requirements for such PPE use including gloves gowns and masks will vary by region and need Users are cautioned to take every available measure to prevent the spread of aerosol and...

Страница 4: ...TION SYMBOLS USED IN THIS GUIDE If the instructions are not followed properly operation may lead to hazards for the product user or patient Useful information that will increase performance or ease of...

Страница 5: ...ng Plate VacTrac Short Handled Mirror 90 Degree HVE Handpiece 4 Adapter with 2 5 Rubber Collar Safe T Shield Screw Pack 8 x 3 Construction Screw 6 10 24 x 1 Machine Screw 4 1 4 20 x 3 4 Machine Screw...

Страница 6: ...950 109 rev A ergonomic products 198 Airport Rd Fall River MA 02720 866 374 6487 PAGE 6 Safe T Shield VacTrac Model T2B1 4 SPECIFICATIONS...

Страница 7: ...VacTrac are done from the center of the headrest on the patient chair in the operating position See below for dimensions NOTES 1 Ceiling shows relation of chair to Vac Track 2 Chair must be in typical...

Страница 8: ...n View Measurements for locationg the VacTrac are done from the center of the headrest on the patient chair in the operating position See below for dimesions Note This manual covers location and insta...

Страница 9: ...this manual are shown installing on a suspeneded ceiling The same approximate procedure is followed for other types of ceilings In planning installation confirm that there are no obstuctions in the ov...

Страница 10: ...ield VacTrac Model T2B1 Install Vac Track Mounting Plate 1 Drill 2 5 8 hole through ceiling tile and backing block See page 7 for location of 2 5 8 hole 2 Install Mount Plate as shown square to ceilin...

Страница 11: ...T Shield VacTrac Model T2B1 Install Vac Track on Mount Plate Hang VacTrac on dado by inserting the hanging lip into the entire length of Mouting Plate dado as shown 6 VACTRAC INSTALLATION cont d 2 1 3...

Страница 12: ...g Track up tight against ceiling 2 Working through Rubber Flap seals with a long philips screw driver carefully install the 4 1 4 20 pan head machine screws 6 VACTRAC INSTALLATION cont d Note End caps...

Страница 13: ...198 Airport Rd Fall River MA 02720 866 374 6487 PAGE 13 Safe T Shield VacTrac Model T2B1 Installing Arm 1 Install VacTrac Arm on Trolly with 4 10 24 machine screws 6 VACTRAC INSTALLATION cont d Trolly...

Страница 14: ...374 6487 PAGE 14 Safe T Shield VacTrac Model T2B1 Connect to Vacuum Source 1 Working from overhead install the Rubber 4 Connection Adapter onto the 2 1 2 VacTrac Outlet Tube 6 VACTRAC INSTALLATION co...

Страница 15: ...TIONING FOR TREATMENT Ideal positioning may vary depending on user preference and treatment requirements However for optimal evacuation and protection from spray and bioburden ejection the Shield shou...

Страница 16: ...al tightening to maintain the proper resistance To Adjust the Height and Location of the Shield Above the Patient Follow the steps below to properly position the Shield above the patient 1 While suppo...

Страница 17: ...the Safe T Shield we found that angled HVE handpieces provided the highest level of comfort and access to the oral cavity while allowing the Shield to best perform it s critical task of controlling t...

Страница 18: ...rter HVE tips allowed better positioning For instance assistants suctioning from the left during treatment of posterior upper left teeth Standard tips may be easily cut to any length desired as shown...

Страница 19: ...susceptible to residue or fogging we recommend using only the cleaning solutions and disinfection products below on the entire unit to avoid accidental contact with the Shield and Manifold Allowed Man...

Страница 20: ...tain a positive patient experience it is vital that this plate is not only thoroughly disinfected but that it LOOKS as clean as possible too An alcohol wipe is effective to remove any streaks or spott...

Страница 21: ...anufacturer s instructions to prepare your fogger for use 4 Turn on the Safe T Shield 5 Place the fogger nozzle in the center of the Suction Tube 6 Fog the tube for 10 seconds only and stop To avoid s...

Страница 22: ...See user manual for cleaning and disinfection recommendations To avoid damaging the Manifold be sure the Airflow Plate is properly installed before inserting the Shield 10 1 10 3 10 2 10 4 To insert...

Страница 23: ...only need to be removed for weekly cleaning To avoid scratching the underside of the Shield remove it prior to inserting or removing the Airflow Plate 11 1 11 3 11 2 11 4 To insert the Airflow Plate 1...

Страница 24: ...E 24 Safe T Shield VacTrac Model T2B1 12 AIRFLOW DAMPER To restrict the airflow when the VacTrac unit it not in use turn the knob in the close position as shown in Fig 12 1 To open the air flow when t...

Страница 25: ...tinued parts or components cannot be serviced once the warranty has expired Additional 3rd party sources may be available We promise to offer you prompt inexpensive repairs Products under warranty wil...