Service and fault display
29
The control panel in the canopy features six indicators to help you localise a variety of faults. The
relevant symbols will flash while servicing or if a fault occurs.
CAUTION
Disconnect the mains plug before gaining access to the interior of the sunbed. In the
case of permanently installed sunbeds, deactivate or remove fuse in order to discon-
nect the sunbed from the power supply.
Symbol
Trouble
Main fan airflow deflector switch not working
Overflow tank full
(Indicator will flash at end of fan run-on)
Facial tanner thermal link has tripped
(operational again after cooling down)
Safety switch, canopy facial tanner filter glass
Safety switch, side section facial tanner filter glass
Trough not closed
Further trouble
Cause / Remedy
UV-lamps and fan do not come on after acti-
vating the timer/control system.
No power.
Check whether fuse/r.c. circuit breaker is
switched on.
Lamps flicker.
Starter faulty. Change starter.
Sunbed gets too hot.
Change dust filter.
Cubicle ventilation and air extraction system
not adequate.
One or more UV lamp(s) not lit.
Tube not in socket or faulty.
Screw tube into socket or change.
UV bulb not in socket or faulty.
Refit bulb or change.
Starting device may be faulty.
Canopy will not remain in raised or lowered po-
sition.
Tighten or relax spring tension.
(See Assembly instructions.)
!