background image

The declared vibration emission value should be used as a minimum level and should be 

used with the current guidance on vibration.

Calculating the actual period of the actual period off use can be difficult and the HSE website 

has further information.

The declared vibration emission been measured in accordance with a standardised test 

stated above and may be used to compare one tool with another tool.

The declared vibration emission value may also be used in a preliminary assessment of 

exposure. 

 

Warning: 

The vibration emission value during actual use of the power tool can differ 

from the declared value depending on the ways in which the tool is used dependant on 

the following examples and other variations on how the tool is used:

How the tool is used and the materials being cut or drilled.

The tool being in good condition and well maintained 

The use the correct accessory for the tool and ensuring it is sharp and in good condition.

The tightness of the grip on the handles. 

And the tool is being used as intended by its design and these instructions. 

While working with this power tool, hand/arm vibrations occur. Adopt the correct

working practices in order to reduce the exposure to vibration.

This tool may cause hand-arm vibration syndrome if its use is not adequately 

managed.

 

Warning: 

identify safety measures to protect the operator that are based on an esti-

mation of exposure in the actual conditions of use (taking account of all parts of the 

operating cycle such as the times when the tool is switched off and when it is running idle in 

addition to the trigger time).Note The use of other tools will reduce the users’ total working 

period on this tool.

Helping to minimise your vibration exposure risk.

ALWAYS use sharp chisels, drills and blades

Maintain this tool in accordance with these instructions and keep well lubricated 

(where appropriate)

Avoid using tools in temperatures of 10ºC or less

Plan your work schedule to spread any high vibration tool use across a number of days.

Health Surveillance

All employees should be part of an employer’s health surveillance scheme to help identity any vibration 

related diseases at an early stage, prevent disease progression and help employees stay in work.

Double insulation

 

The tool is double insulated.   This  means  that  all  the  external metal parts are electrically 

insulated from the mains power supply. This is done by placing insulation barriers between 

the electrical and mechanical components making it unnecessary for the tool to be earthed.

Important note

Be sure the supply is the same as the voltage given on the rating plate. The tool is fitted with 

a two-core cable and plug.

Remove the mains plug from socket before carrying out, any adjustment or servicing.

Содержание ERA568RSP

Страница 1: ...1100W 110V RECIPROCATING SAW ERA568RSP ERA568RSP...

Страница 2: ...Original Instructions Version 1 0...

Страница 3: ...use of the goods This guarantee does not affect your statutory rights This guarantee is only valid in the UK For further technical advice spare parts or repair service outside of guarantee please con...

Страница 4: ...ging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an extension cord...

Страница 5: ...condition that may affect the power tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools f Keep cutting tools sharp and clean...

Страница 6: ...ing blade foot must be held firmly against the material being cut to reduce saw vibration blade jumping and blade breakage 17 If possible ensure the work piece is firmly clamped to prevent movement 18...

Страница 7: ...truction jobs contain chemicals known to cause cancer birth defects or other reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silica from bricks and cemen...

Страница 8: ...s not adequately managed Warning identify safety measures to protect the operator that are based on an esti mation of exposure in the actual conditions of use taking account of all parts of the operat...

Страница 9: ...Wear ear protection Wear eye protection Wear dust mask Wear safety gloves Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your...

Страница 10: ...1 BLADE 2 PIVOTING BLADE FOOT 3 SAW BLADE HOLDER 4 TOOL FREE BLADE CLAMP BUTTON 5 LED LIGHT 6 ON OFF SWITCH 7 HAND GRIP AREAS 8 HEX KEY 5mm 1 2 3 6 7 8 5 4...

Страница 11: ...capacity max Wood 300mm Protection class Machine weight II 3 5kg NOISE INFORMATION A weighted sound pressure LpA 78dB A KpA 3 0dB A A weighted sound power LwA 89dB A KwA 3 0dB A Wear ear protection wh...

Страница 12: ...a thin saw blade for narrow curve cuts 2 INSERTING A SAW BLADE Press the tool free blade clamp lever 4 and hold Insert the blade into the saw s blade clamp and make sure that the blade attaches to th...

Страница 13: ...ng the stroke rate is recommended when the saw blade engages in the material as well as when sawing plastic and aluminium 4 CUTTING INSTRUCTION Plunge cutting See Fig 4 The plunge cutting procedure is...

Страница 14: ...n increase to the correct speed METAL CUTTING This saw has different metal cutting capacities depending upon the type of blade being used and metal being cut Use a finer blade for ferrous metals and a...

Страница 15: ...ur power tool Never use water or chemical cleaners to clean your power tool Wipe clean with a dry cloth Always store your power tool in a dry place Keep the motor ventilation slots clean Keep all work...

Страница 16: ...which is coloured blue must be connected to the terminal which is marked with N The wire which is coloured brown must be connected to the terminal which is marked with L Warning Never connect live or...

Страница 17: ...95 EC EC Electromagnetic Compatibility Directive 2004 108 EC Restrictions of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment 2011 65 EU Waste Electrical and Electronic...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: