IMPORTANT: The wires in the mains lead are colored in
accordance with the following code:
Blue – Neutral Brown – Live Green/Yellow – Earth
As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings
identifying the terminals in your plug, proceed as follows:
The blue wire must be connected to the terminal marked with an N or colored black. The brown wire must
be connected to the terminal marked with an L or colored red. The green/ yellow wire must be connected
to the earthing terminal which is marked with an E or with the earth symbol.
NOTE:
If a moulded plug is fitted and has to be removed take great care in disposing of the plug and
severed cable, it must be destroyed to prevent engaging into a socket.
WARNING: Never connect live or neutral wires to the earth terminal of the plug.
Troubleshooting
You can solve many common problems easily, saving you the cost of a possible service call. Try the
suggestions below to see if you can solve the problem before calling the service centre.
Problem
Possible cause
Treatment
The heater does not
operate, even when it is
plugged in and the switch,
thermostat are switched
on.
The plug is loose, bad
connection.
Pull out the plug, check the connection of the
plug and socket. Then connect again.
No power in socket
outlet.
Insert the plug in a proper socket.
The heating element
glowing.
The input voltage is
too high or too low.
Use power supply according to the rating on the
label.
The air inlet grill is
blocked.
Keep the heater far way from articles like
curtain, plastic bag, paper and other things
which can cover the inlet or can be easily cover
on the air inlet.
The appliance didn’t heat
up, or only ventilator
worked.
The switch was not
put at heating setting.
Turn the switch to heat setting.
The thermostat
operated.
Turn the thermostat and listen if there is
open/close voice. If there is no click and the
thermostat is not damaged, the heater will
automatic switch on when the appliance cooled
down.
The self-resetting
cut-out operated.
Turn the heater off and inspect the blockage of
inlet or outlet.
Disconnect the plug and wait at
least 10 minutes
for the protection system to
reset before attempting to restart the heater.
Abnormal noise.
The appliance is not
stands upright.
Put the heater on a level surface.