4-1.6 J20 : PSU Power Connector
Pin No
I/O
Specification
Description
1 ( 5V )
I
5V
VSC 5V Input
2 ( 5V )
I
5V
VSC 5V Input
3 ( 5V )
I
5V
VSC 5V Input
4 ( GND )
GND
5V Ground
5 ( GND )
GND
5V Ground
6 ( GND )
GND
5V Ground
7 ( 12V )
I
12V
VSC 12V Input
8 ( 12V )
I
12V
VSC 12V Input
9 ( GND )
GND
12V Ground
10 ( GND )
GND
12V Ground
11 ( 12V )
I
12V
FAN 12V
J20
12 ( GND )
GND
FAN 12V Ground
4-1.7 J19 : PSU Power Detect Connector
Pin No
I/O
Specification
Description
1 ( AC-DET )
I
5V / 0V
AC POWER DETECT PORT
: AC INPUT DETECTING.
: AC POWER ON
à
High ,
AC POWER OFF
à
LOW
: Turn off the power by power sequence to
stabilize PDP MODULE in case of power
breakdown.
2 ( RL -ON )
O
5V / 0V
RELAY CONTROL PORT FOR POWER ON
: Relay On
à
High, Relay off
à
Low
3 ( 5V STBY )
I
5V
5V INPUT PORT FOR VSC STANDBY
4 ( GND )
5 (VAVS-ON )
O
5V / 0V
PORT FOR VA/VS OF PDP MODULE.
: ON
à
HIGH , OFF
à
LOW
: To protect PDP MODULE, Micom turn on the
Va/Vs 2 seconds after checking 5V-MNT.
6 ( 5V-MNT )
I
5V / 0V
PDP MODULE STABLE CHECK PORT.
: The port to provide control signal to PDP
MODULE after the controller stabilized. At the
moment, MICOM always check this signal and
turn off the power when the signal is low.
J19
7 ( N.C )
Содержание EPT4220AP
Страница 11: ...MANUAL _ EPT 4220AP ERAE ELECTRONICS 11 2 1 Package Overview...
Страница 13: ...MANUAL _ EPT 4220AP ERAE ELECTRONICS 13 2 2 Exploded Overview 2 2 1 PDP SET OVER VIEW...
Страница 14: ...SERVICE 14 2 2 2 PDP MODULE OVERVIEW...
Страница 19: ...MANUAL _ EPT 4220AP ERAE ELECTRONICS 19 9 VSC BOARD ASSY 10 Tuner B D Assy...
Страница 22: ...SERVICE 22 3 Unscrew 19 m screws of BACK COVER 4 Unscrew 7 m screws 6 t screws 1 nut COVER JACK...
Страница 41: ...MANUAL _ EPT 4220AP ERAE ELECTRONICS 41 4 7 Power Board 4 7 1 The Location of Connector and Specification...
Страница 75: ...MANUAL _ EPT 4220AP ERAE ELECTRONICS 75 5 Click Flash to upgrade program...