background image

www.prolight.co.uk

Saturn Spot 

User Manual

2

Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 100~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again. 
 

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: One year from date of purchase.

Содержание Saturn Spot

Страница 1: ...Order code EQLED023 Saturn Spot User Manual...

Страница 2: ...short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is no...

Страница 3: ...e LED 76 x tri colour 5050 SMD LEDs RGB Beam angle 3 16 000 Lux 2m Flicker free projection Individually controllable LED rings with stepless RGB colour changing Gobo wheel 9 static gobos open Colour w...

Страница 4: ...V POWER INPUT 100 240V 50 60Hz POWER CONSUMPTION 90W www prolight co uk 03 05 04 02 01 07 06 08 01 LED display 02 Function buttons 03 Microphone 04 DMX input socket 05 DMX output socket 06 IEC power i...

Страница 5: ...1 A 5 1 2 A d d r DMX address setting 1 2 C h 2 3 C h C h n d Channel modes L o S t No DMX signal A u t o S o u n h o L d b L A C N A s t S L 1 S L n d Master slave mode S h 1 S h 3 S h n d Show modes...

Страница 6: ...ng instructions y E S n o t I n t Tilt invert P 0 0 0 P 2 5 5 P A d J Pan fine t 0 0 0 t 2 5 5 t A d J Tilt fine O n o F F L E d LED backlight O n o F F d I S P Display invert H F h r s Fixture hours...

Страница 7: ...o set the required DMX address Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button DMX channel mode To access the DMX channel mode press the MEN...

Страница 8: ...o 5 Shaking 204 216 Gobo 6 Shaking 217 229 Gobo 7 Shaking 230 242 Gobo 8 Shaking 243 255 Gobo 9 Shaking Channel Value Function CH8 000 029 SMD ring strobe off 030 225 SMD ring strobe slow fast 226 255...

Страница 9: ...229 Gobo 7 Shaking 230 242 Gobo 8 Shaking 243 255 Gobo 9 Shaking CH10 000 255 Inner SMD ring red dimmer 0 100 Channel Value Function CH11 000 255 Inner SMD ring green dimmer 0 100 CH12 000 255 Inner S...

Страница 10: ...in 156 160 Red Green Blue White Effect 161 165 Yellow Magenta Cyan White Effect 166 255 Colour chase CH22 000 255 SMD ring speed slow fast CH23 000 049 No function 050 099 Auto program 1 100 149 Auto...

Страница 11: ...he MENU button Please ensure that all slave units are set to the same DMX channel mode as the master unit DMX signal lost To change what the unit does when the DMX signal is lost press the MENU button...

Страница 12: ...5 Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Tilt fine setting To access the tilt fine setting press the MENU button and use the UP and...

Страница 13: ...n and the software version will be displayed To exit out of any of the above options press the MENU button Motor reset To reset the units motors press the MENU button and use the UP and DOWN buttons o...

Страница 14: ...language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure prope...

Страница 15: ...n XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR...

Страница 16: ...ible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material re...

Отзывы: