background image

www.prolight.co.uk

MicroPar RGBW/MidiPar RGBW

  

User Manual

7

Notice:

Be sure to follow the diagrams below when making your own cables. Do not connect the cables  
shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs  
outer casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special note: 

Line termination:

When longer runs of cable are used,  
you may need to use a terminator on  
the last unit to avoid erratic behaviour.

Using a cable terminator will decrease  
the possibilities of erratic behaviour. 
(3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)

5-pin XLR DMX connectors:

Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 
3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion.

Termination reduces signal transmission 

problems and interferance. it is always 

advisable to connect a DMX terminal, 

(resistance 120 Ohm 1/4 W) between pin 2 

(DMX-) and pin 3 (DMX+) of the last fixture.

5-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

3-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

3-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

5-pin XLR (socket)

Pin 1: GND (screen)

Pin 2: Signal (-)

Pin 3: Signal (+)

Pin 4: N/C

Pin 5: N/C

DMX setup

Содержание MicroPar RGBW

Страница 1: ...Order codes MicroPar RGBW EQLED130 MidiPar RGBW EQLED131 MicroPar RGBW MidiPar RGBW User Manual...

Страница 2: ...off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipmen...

Страница 3: ...imming and variable strobe 4 push button menu with LED display Captive power connection 3 Pin XLR input output Fan cooled 54 x 1W LEDs R 12 G 18 B 18 W 6 Beam angle 25 3600 Lux 2m full on DMX channels...

Страница 4: ...ress the MENU button 01 Hanging bracket 02 Hanging bracket adjustment knob 03 LED display 04 Function buttons 05 Captive power connection 06 Fuse F3A 250V 07 3 Pin XLR DMX input 08 3 Pin XLR DMX outpu...

Страница 5: ...ons press the MENU button Static colour mode To access the static colour mode press MENU until r 225 shows on the LED display Now use the UP and DOWN buttons to select the brightness between r 000 r 2...

Страница 6: ...X is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensur...

Страница 7: ...89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 p...

Страница 8: ...ife To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable r...

Отзывы: