background image

Built-in programme chart

 Equinox Megabar   

 

 

 

 

                                        Operation modes

Static Colour
BLAC-RGB   Flash00-99
Dream
Speed00-99   Flash00-99
Meteor
Speed00-99   Flash00-99
Fade
Speed00-99   Flash00-99
Change
Speed00-99   Flash00-99
Flow 1
Speed00-99   Flash00-99
Flow 2
Speed00-99   Flash00-99
Flow 3
Speed00-99   Flash00-99
Flow 4
Speed00-99   Flash00-99
Flow 5
Speed00-99   Flash00-99
Flow 6
Speed00-99   Flash00-99
Flow 7
Speed00-99   Flash00-99
Flow 8
Speed00-99   Flash00-99
1. BLAC-RGB 2. BLAC-RGB
Flow 9
Speed00-99  Flash00-99
1. BLAC-RGB 2. BLAC-RGB

Red-Yellow-Green-Cyan-Blue-Purple-White-Blackout
Flash speed adjustable
7 colour dreaming
Speed & Flash adjustable
7 colour flow
Speed & Flash adjustable
7 colour fade
Speed & Flash adjustable
7 colour change
Speed & Flash adjustable
7 colour chase in 1 direction
Speed & Flash adjustable
7 colour chase in 2 directions
Speed & Flash adjustable
7 colour relay chase in 1 direction
Speed & Flash adjustable
7 colour relay chase in 2 directions
Speed & Flash adjustable
7 colour chase from sides to centre
Speed & Flash adjustable
7 colour chase from centre to side
Speed & Flash adjustable
7 colour chase
Speed & Flash adjustable
2 colour chase in 1 direction
Speed & Flash adjustable
Red-Yellow-Green-Cyan-Blue-Purple-White-Blackout
2 colour chase in 2 directions
Speed & Flash adjustable
Red-Yellow-Green-Cyan-Blue-Purple-White-Blackout

Содержание Megabar System EQLED63

Страница 1: ...w w w p r o l i g h t c o u k ...

Страница 2: ...CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written ...

Страница 3: ...le periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reac...

Страница 4: ...lour LEDs total 7 x RGB tri colour per panel 14 built in programmes 4 Push button LCD digital display Beam angle 25 Mains IEC Power In Out sockets 3 Pin XLR In Out sockets for DMX 5 Pin socket for foot controller MB 1 Power consumption Max 100W Power supply 240V Dimensions 1030x 100 x 290mm Weight 7Kgs Fuse F2A Overview Identification 1 Power output 2 Power input 3 On Off switch 4 Remote input 5 D...

Страница 5: ...t the desired flash speed level 00 99 Finally press the SETUP button to confirm your setting 3 Auto Run mode To select the Auto run mode press the MODE button to show AUTO RUN in the LCD display window Now press the SET UP button to adjust the frequency level FQN01 99 Finally press the SETUP button to confirm your setting The unit will now run all 13 built in programmes one after another 4 DMX mod...

Страница 6: ...lash speed adjustable 7 colour dreaming Speed Flash adjustable 7 colour flow Speed Flash adjustable 7 colour fade Speed Flash adjustable 7 colour change Speed Flash adjustable 7 colour chase in 1 direction Speed Flash adjustable 7 colour chase in 2 directions Speed Flash adjustable 7 colour relay chase in 1 direction Speed Flash adjustable 7 colour relay chase in 2 directions Speed Flash adjustabl...

Страница 7: ...dividually Equinox Megabar DMX Charts CH 4 Red pods 3 4 CH 5 Green pods 3 4 CH 6 Blue pods 3 4 CH 7 Red pods 1 2 CH 8 Green pods 1 2 CH 9 Blue pods 1 2 CH 4 Red pod 4 CH 5 Green pod 4 CH 6 Blue pod 4 CH 7 Red pod 3 CH 8 Green pod 3 CH 9 Blue pod 3 CH 10 Red pod 2 CH 11 Green pod 2 CH 12 Blue pod 2 CH 13 Red pod 1 CH 14 Green pod 1 CH 15 Blue pod 1 ...

Страница 8: ...orm the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the co...

Страница 9: ...a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conv...

Страница 10: ...MODE foot switch so the G LED indicator is lit now the unit will work to the music If you require to blackout the unit at any point press the BLACKOUT foot switch and press it again to return it to the previous setting Built in programmes To activate this mode press the MODE foot switch so the Y LED indicator is lit now use the UP and DOWN foot switches to select the desired built in programme To ...

Страница 11: ...Notes Equinox Megabar Notes ...

Страница 12: ......

Отзывы: