Equflow 6010BCPM Pulse Input Batch Controller Instruction Manual
48
Factory Defaults & User Settings
The following table shows the factory setting for the major programmable parameters on the controller.
Parameter
Display
Default Setting
Input type
Input
Pulse
Total
yes
Total enabled
Units
units
Rate / total / gr. total
Pulse / Pulse / Pulse
Rate decimal
point
ddd.ddd
1 Place
Total decimal
point
ddddd.d
1 Place
G. Total
decimal point
dddddd
0 Places
K-factor
Factor
1.000
Function
Functn
Linear
Number of
points
No Pts
2
Programming
prog
Scale
Input 1
InP 1
00000.0
Display 1
Dis 1
00000.0
Input 2
InP 2
10000.0
Display 2
Dis 2
10000.0
Display line 1
Line 1
Display total
Display line 2
Line 2
Display rate and units
Display
intensity
d-Inty
8
Total time
base
T tb
Second
Total
conversion
factor
T CF
1.000
Batch mode
mode
Manual
Grand total
time base
GT tb
Second
Grand total
conversion
factor
T CF
1.000
Grand total
reset
T rst
Manual
Relay 1
assignment
Asign1
Total
Relay 2
assignment
Asign2
Total
Relay 2
preclose
preCls
No
Relay 1
action
Act 1
Automatic
Batch preset
Preset
100.0
Parameter
Display
Default Setting
Relay 2
action
Act 2
Automatic
Relay 2 set
point
Set 2
200.0
Fail-safe
relay 1
Fls 1
Off
Fail-safe
relay 2
Fls 2
Off
On delay
relay 1
On 1
0.0 sec
Off delay
relay 1
Off 1
0.0 sec
On delay
relay 2
On 2
0.0 sec
Off delay
relay 2
Off 2
0.0 sec
Filter
filter
Hi Spd
Cutoff value
CutofF
0.000 (disabled)
Maximum
output
mAx
23.000 mA
Minimum
output
min
1.000 mA
Slave ID
(Address)
Slave
Id
247
Baud rate
baud
9600
Transmit
delay
Tr dly
50 ms
Parity
Parity
Even
Byte-to-byte
timeout
t-byt
010 (0.1 sec)
F1 function
key
F1
Start
F2 function
key
F2
Preset
F3 function
key
F3
Stop
F4 function
F4
Start/Stop
Digital input 1
dI 1
Menu
Digital input 2
dI 2
Right arrow
Digital input 3
dI 3
Up arrow
Digital input 4
dI 4
Enter
Digital output
1-4
dO 1
Alarm 1-4
Password 1
Pass 1
000000 (unlocked)
Password 2
Pass 2
000000 (unlocked)