8
4.6
FA1TM TOOL MAINTENANCE
INSPECTION
A thorough inspection should be carried out prior
to usage, storage or transportation to ensure the
completeness and condition of the tool.
Inspection should include:
•
visual inspection of the outer parts of the tool,
checking for obvious damage, degradation or
missing parts.
Cleaning and servicing should be undertaken as
required prior to the tool being used, stored or
transported.
CLEANING
To lightly clean the tool, wipe gently with a damp
cloth.
If more thorough cleaning is required (for example
following immersion in water) carry out the following
cleaning procedure:
• strip the tool down, observing the schematics in
section 8
• clean the components using detergent, following
the manufacturer’s guidelines
•
rinse the components to remove traces of
detergent
•
dry the component thoroughly
Inspect, service and lubricate the tool immediately
after the cleaning process.
SERVICING
Replace missing, worn or damaged parts. Use only
genuine Equalizer parts from approved distributors
or service centres. Equalizer parts have been
engineered and manufactured to be fit for purpose.
Grease all moving parts by following the Lubrication
Procedure prior to usage, storage or transportation.
Ensure wedges, pins and legs remain grit free and
that parts move freely.
4.5
FA1TM TOOL DIMENSIONS
MINIMUM EXTENSION
151 mm
(5.94”)
50 mm
(1.97”)
54 mm
(2.13”)
31 mm
(1.22”)
38 mm
(1.50”)
MAXIMUM EXTENSION
50 mm
(1.97”)
89 mm
(3.50”)
21 mm
(0.83”)
82 mm
(3.23”)
72 mm
(2.83”)
5 mm
(0.2”)
194 mm
(7.64”)
35 mm
(1.38”)
Содержание FA1TM