4
3.
FLANGE MISALIGNMENT
DETERMINATION
PROCEDURE
The
tool being used must not be attached to a
flanged joint prior to the misalignment procedure
being carried out.
3.1
LATERAL MISALIGNMENT
1. Loosen and remove every second bolt around
the flange. Continue with this until misalignment
occurs.
A flanged joint, once broken down, may spring
out of alignment at any point or in any direction
around its circumference. Misalignment may not
occur until only a few bolts remain.
2. At this point the direction of any misalignment
should become obvious. The alignment tool
being used should be attached at the maximum
point of misalignment (point A or B in the
examples shown below).
POINT A
POINT B
POINT A
POINT B