17
The air pressure is influenced by the speed at which the fan rotates. Adjustments to the fan speed
will regulate the air pressure.
NOTE:
THE OIL PRESSURE READING ON THE OIL PRESSURE GAUGE (MPa) MAY NOT
EXCEED 15 MPa.
NOTE:
Settings from the table must be done while the planter is stationary. No product may flow
through the pipes while the set up takes place. The air pressure reading will increase and settle at a
higher value when application starts. The above values serve only as a guideline.
CARRY OUT THE NECESSARY AIRFLOW TEST (REFER 3.3.4) TO MAKE SURE THE
PRESSURE IS SUFFICIENT.
For general setup use the following table as a guide for the adjustment of the pressure. Only for
Equalizer Min-Till air hopper with model numbers specified.
PRESSURE READINGS ARE SPORADIC
Make sure that all pressure gauges are working 100%. If the planter is attached directly to the
tractor, and the pressure jumps around, test the various ports in the tractor.
If the planter is linked to the tractor through a PTO powerpack, make sure the flow regulating valve
on the pump is not faulty.
MODEL
AIR PRESSURE
LOWEST
READING
HYDRAULIC
PRESSURE
MPa
4000E, 4500E
2 kPa
6 MPa
5000E, 5500E
2 kPa
7 MPa
6000E, 6500E
2 kPa
8 MPa
5000,5500
2.5 kPa
7 MPa
6000,6500
2.5 kPa
8 MPa
7000,7500
2.5 kPa
9 MPa
8000,8500
2.5 kPa
10-11 MPa
9000,9500
3 kPa
11-12 MPa
10000,10500
3 kPa
12-13 MPa
11000,11500
3 kPa
13 MPa
12000,12500
3 kPa
14 Pa
TOTAL APPLICATIONS
QUANTITY KG/HA
AIR PRESSURE
LOWEST READING
5-50 kg/ha
1.5 kPa
50-125 kg/ha
1.5 – 2.0 kPa
125-200 kg/ha
2.0 – 2.8 kPa
200-275 kg/ha
2.8 – 3.5 kPa
275-350 kg/ha
3.5 – 4.0 kPa